Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual page 358

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents
344/407
Commissioning, operation, diagnostics and maintenance
LED
Color / status
H52.5
Drives
Flashing
H53
42V Out
H54
DC Bus Out
Bosch Rexroth AG R911335703_Edition 04
Significance
Green
No error at module bus, regular
status
Red
Module bus error (/Bb_A)
Red/
Drive system carries out error
green
reaction (Bb_A)
Green
Control voltage at output X53 okay
Red
Control voltage at output X53 faulty
or control voltage outside of
tolerance
Error is saved until switch-off
Off
DC bus (L+, L-) not ready for power
output
Green
DC bus (L+, L-) ready for power
output
Red
DC bus voltage (L+; L-) at output
X54 not okay
Tab. 11-3:
KCU02 LED displays
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Measures
None
Check module bus wiring
Check control voltage supply of the
devices; see also "F2087 Module group
communication error"
Bring device at module bus to readiness for
operation; see also diagnostic message "E2810
Drive system not ready for operation"
None
Overload at output:
Check control voltage supply
Check voltage at X53
Reduce load
Remove short circuit
None
None
Check fuses F4, F5 and replace them, if
necessary
Table of Contents
loading

Table of Contents