Selecting Rkh Hybrid Cable Incl. Communication - Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents
118/407
Technical data of the components
5.9.3

Selecting RKH hybrid cable incl. communication

KCU02
HCS01
X103.2
1)
X103.2
2)
X103.2
3)
RKH0700
Circular
connector
Bosch Rexroth AG R911335703_Edition 04
Use the table below to select an RKH hybrid cable for the appropriate
connection with different outgoing directions from connection point X103.1 or
X103.2.
1)
X103.1
X103.1
RKH0311
RKH0411
RKH0341
RKH0441
5)
RKH0011
RKH0111
RKH0110
RKH0210
RKH0212
RKH0214
RKH0212
RKH0214
RKH0902
RKH0905
1)
Outgoing direction "A"
2)
Outgoing direction "B"
3)
Outgoing direction "V"
4)
To interconnect two RKH0700 cables, use a short RKH0610
cable as an intermediate piece
5)
HCS01.1E-W0054 with
Tab. 5-21:
RKH hybrid cable
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Target
2)
3)
X103.1
RKH0700
RKH0511
RKH0511
RKH0541
RKH0541
RKH0213
RKH0213
RKH0215
RKH0215
RKH0610
RKH0610
RKH0610
-
RKH0907
tbd
HAS05.1-023
accessories
Circular
connector
RKH0903
RKH0909
RKH0901
RKH0904
RKH0906
tbd
4)
RKH0900
Table of Contents
loading

Table of Contents