Installation; Installation Directives; Lifting Methods - Bosch Rexroth Hägglunds DOb Installation And Maintenance Manual

Drive unit
Table of Contents

Installation

23/80
7 Installation

7.1 Installation directives

If the drive unit is to work properly it must be installed in accordance with these
instructions. The conditions the unit will operate in must be taken into consideration.
Improper installation, not following the instructions in this manual and in the attached
technical documentation, may affect the function and/or the service life of the drive
unit. It is important that the safety precautions in this manual always are followed.
Position the drive unit:
• on a firm level foundation to avoid vibrations.
• to ease maintenance and service (see 7.3: Positioning the drive unit).
• protected from weather, airborne sprays, heavy contaminations and radiated heat.
• to ensure free ventilation for cooling purposes for the electric motor and the air-oil
cooler.
• to minimize pipe runs.
Clamp each pipe in the pipe run separately and attach it to a firm foundation to
avoid vibration. The hydraulic connections from the drive unit must always be fitted
to the piping with hoses.

7.2 lifting methods

lifting with fork lift
See 6.2: Lifting the packed drive unit section lifing with fork lift.
DD00083914
Fig. 7: Maximum width of forks lifting drive unit
Hägglunds DOb, RE 15327-WA/05.2017, Installation and maintenance manual, Bosch Rexroth AB