Parameter
Value
Name
E1.00
30
X1 input(Digital)
E1.01
33
X2 input (Digital)
E1.02
35
X3 input (Digital)
E1.03
41
X4 input (Digital)
E1.04
31
X5 input (Digital)
E1.35
1
AI 1 input
E1.40
1
AI 2 input
E1.61
2
Broken wire protection
Input curve 1 maximum
E1.73
100
frequency
E2.01
1
DO1 output setting
E4.00
4
PID reference channel
E4.01
0
PID feedback channel
U1.00
1
Run monitoring display
U1.10
3
Stop monitoring display
Hägglunds DOb, RE 15327-WA/05.2017, Installation and maintenance manual, Bosch Rexroth AB
VFD (Variable frequency drive)
Comment
E1: Input terminal parameters
30: Second frequency setting source
activation (potentiometer → analog in)
Fault signal N.C contact input
• Max oil temperature error or
• Min oil level error or
• High main motor temperature
Forward runniing
PID deactivation
Second run command source activation
1: 4-20 mA setting range
Actual Speed or pressure for feedback
1: 4-20 mA setting range
Set speed in remote mode
2: Broken wire detection for analog inputs
Setting range is 0...E0.09 Hz
E2: output terminal parameters
Indication of converter running(Start signal
for cooler drive)
E4: PID control parameters
AI 2 analog input
AI 1 input
U1:Panel parameters
Actual speed
Setting speed
49/80