Maintenance And Repair; Maintenance Log; Preventive Maintenance - Bosch Rexroth Hägglunds DOb Installation And Maintenance Manual

Drive unit
Table of Contents
62/80

Maintenance and repair

Bosch Rexroth AB, Installation and maintenance manual, Hägglunds DOb, RE 15327-WA/05.2017
10 Maintenance and repair

10.1 Maintenance log

We recommend that a maintenance log is kept to record service/maintenance/repair,
addition and alteration of the equipment. Each note, observation or comment should
be dated.

10.2 Preventive maintenance

Common
The maintenance of hydraulic systems is designed to prevent failure of the system
and to keep the system running efficiently to specification. The specific procedures
will depend on the nature of the equipment, the environment it is working in and
the duty cycle, bearing in mind the consequences of a breakdown. To optimise
the maintenance intervals economically a Life Cycle Cost (LCC) analysis is
recommended.
Follow the 2: Safety instructions during the checks.
The panels covering the drive unit can be dismounted to simplify the access to the
components inside the unit.
Daily checks, first week after commissioning
… Fluid leaks
… Fluid level in the tank
… Operating temperature
… System pressure
… System performance and general condition
… Unusual noises
… Contamination indicators on the filters
Pre-start checks (even daily)
… Fluid leaks
… Fluid level in the tank
… Contamination indicator on the filters
Frequent checks
… Unusual vibrations or noises
… Fluid leaks
… Fluid level in the tank
… The unit is clean
… The air flow paths not are blocked
… Pressure levels normal - stable
… Operating temperature
… The drive is running smoothly
… Contamination indicators on the filters
… Check and clean the oil pan
Table of Contents
loading