Bosch Rexroth Hägglunds DOb Installation And Maintenance Manual page 32

Drive unit
Table of Contents
32/80
Installation
Table 8: Terminals, control cabinet
Block Number Type
-X0
1
Mains power supply
2
3
4
PE
-X3
1
Temp/Level sensor digital signals
2
3
4
5
Filter switch
6
7
8
-X4
1
Main motor thermistor
2
3
Temp/Level sensor analog signals
4
5
6
7
Speed sensor
8
9
10
11
Pressure sensor
12
13
Jumpers for
14
pressure feedback
15
16
17
Remote drive start
18
19
Remote speed / pressure setpoint
20
-X5
1
Sum alarm indication
2
3
Emergency stop indication
4
5
Pressure signal
6
7
Speed signal
8
9
Power off input (JUMPER IF NOT USED)
10
Signal must be isolated in external system
*)
Bosch Rexroth AB, Installation and maintenance manual, Hägglunds DOb, RE 15327-WA/05.2017
(JUMPER IF NOT USED)
*
*
(JUMPER IF NOT USED)
Function
L1
L2
L3
Neutral (not used)
Protective earth
+24 VDC
High temperature
0 VDC
Low level
+24 VDC
Not used
0 VDC
Filter clogged
A-side
B-side
+24 VDC
Temperature
0 VDC
Level (not used)
0 VDC
+24 VDC
Pulse train
Not used
+24 VDC
+4-20 mA
Jumpers for
Pressure signal
speed feedback
0 VDC
Speed signal
Signal input to regulator
+24 VDC
Start input
+4-20 mA
4-20 mA return
Dry contact A
Dry contact B
Dry contact A
Dry contact B
+4-20 mA out (0-400 bar)
4-20 mA return
+4-20 mA out (0-2.7 rpm)
4-20 mA return
+24 V
Out
Table of Contents