Bosch Rexroth Hägglunds DOb Installation And Maintenance Manual page 29

Drive unit
Table of Contents
Cleaning
The pipes and hoses should be pre cleaned, inspected and sealed by the supplier. If
the pipes are field bent and installed the overall system must be carefully oil flushed
to reach the required cleanliness level.
Mounting of hoses
Ensure that hoses not are stressed or twisted on installation, to avoid premature
failure. Bend radius should conform to manufacturers recommendations.
DD00073548
Fig. 14: Mounting of hoses
Hägglunds DOb, RE 15327-WA/05.2017, Installation and maintenance manual, Bosch Rexroth AB
Right
Wrong
Right
Right
Right
Right
Installation
Wrong
Wrong
Wrong
Wrong
29/80
Table of Contents
loading

Table of Contents