5. Switch the converter off and on again. The firmware of the connected DRIVE-CLiQ
components is updated. This may require a restart (see alarm messages in the web server).
6. Check whether the new version is installed. The firmware version of the converter is
displayed on the home page of the web server under the converter.
SINAMICS S210 servo drive system
Operating Instructions, 01/2019, A5E41702836B AC
RDY
Explanation of the LED displays
Firmware update in progress for the connected DRIVE-CLiQ components.
● Do not switch off the power supply.
● Do not disconnect the motor from the converter.
DRIVE-CLiQ component firmware update has been completed.
Waiting for POWER ON of the corresponding components.
Remedy: Switch the component off and on again.
Commissioning and diagnostics using the web server
6.6 System settings in the web server
247