Siemens SINAMICS S210 Operating Instructions Manual page 448

Servo drive system, converter, servomotor
Hide thumbs Also See for SINAMICS S210:
Table of Contents
Faults and alarms
15.2 List of faults and alarms
Remedy:
For fault value = 130:
- carry out safety commissioning routine.
For fault value = 1000:
- again carry out safety commissioning routine.
- replace the memory card or drive.
For fault value = 2000:
- confirm the data change using the commissioning tool.
For fault value = 2001:
- confirm the data change using the commissioning tool.
For fault value = 2002:
- using the commissioning tool, copy the safety parameters and confirm the data change.
For fault value = 2003, 2004, 2005:
- carry out an acceptance test and generate an acceptance report.
Note:
The fault with fault value 2005 can only be acknowledged when the "STO" function is deselected.
For fault value = 2010:
- check that safe brake control is enabled.
- using the commissioning tool, copy the safety parameters and confirm the data change.
For fault value = 2020:
- again carry out safety commissioning routine.
- replace the memory card or drive.
For fault value = 3003:
- carry out the function checks for the modified hardware and generate an acceptance report.
For fault value = 3005:
- carry out the function checks for the modified hardware and generate an acceptance report.
Note:
The fault with fault value 3005 can only be acknowledged when the "STO" function is deselected.
For fault value = 9999:
- carry out diagnostics for the other safety-related fault that is present.
Note:
SI: Safety Integrated
STO: Safe Torque Off
F01651
SI P1: Synchronization safety time slices unsuccessful
Reaction:
OFF2
Acknowledge:
IMMEDIATELY
Cause:
The "Safety Integrated" function requires a synchronization of the safety time slices between the two monitoring channels
and between the drive and the higher-level control. This synchronization routine was unsuccessful.
Note:
This fault results in an STO that cannot be acknowledged.
Remedy:
- carry out a POWER ON (switch-off/switch-on).
- upgrade the drive software.
- upgrade the software of the higher-level control.
Note:
SI: Safety Integrated
STO: Safe Torque Off
F01653
SI P1: PROFINET configuration error
Reaction:
NONE
Acknowledge:
IMMEDIATELY
446
SINAMICS S210 servo drive system
Operating Instructions, 01/2019, A5E41702836B AC

Hide quick links:

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fk2

Table of Contents