Wiring For Zone Trigger Mode - Honeywell AlarmNet 7845i-GSM Installation And Setup Manual

Internet communication
Hide thumbs Also See for AlarmNet 7845i-GSM:
Table of Contents
To install a 7845i-GSM with a LynxR-I Security System, wire the devices as shown in
Figure 3. Refer to the LynxR-I Installation and Setup Guide.
LYNX
(OPTIONAL)
SUPER HIGH
REQUIRED FOR
CAPACITY
24-HR BACKUP
BATTERY

Wiring for Zone Trigger Mode

To trip a zone on the 7845i-GSM in V+ trigger mode, the positive triggering voltage from the
control panel must be within 2.0V-14.5V.
Trigger levels above this range may cause permanent damage to the unit.
Trigger levels below this range result in unreliable operation.
To trip a zone on the 7845i-GSM in V- trigger mode, the negative triggering voltage must be
less than 1.0V.
NOTE: LynxR and LynxR-EN have a designated trigger for V+ trigger.
Connect a wire from the triggering source (bell output, voltage trigger, etc.) of the control
panel to the zone input of the module, and connect a common ground between the module
and control panel.
Examples of zone connections are shown below:
CONTROL PANEL
Figure 4. Wiring the 7845i-GSM Zone 1 Input for a Positive (+) Triggered Bell Output
4-WIRE CABLE (N4632-4)
LRR/IP COMMUNICATIONS PORT
LYNXR-I CONTROL PANEL
LYNX
STANDARD
CAPACITY
BATTERY
Figure 3. Wiring a LynxR-I for ECP Mode
TRANSFORMER
MODEL No. 1332
+12 V AUX
GND
BELL (+)
BELL ( )
(+)
( )
Section 2: Mounting and Wiring
TB1
1
2
RED
ECP (+) VOLTAGE INPUT
3
4
BLK
4
GND
YEL
5
5
Z1/Z2 OR DATA IN
GRN
6
Z3 OR DATA OUT
7845i-GSM
7845i-GSM-010-V0
TB1
AC INPUT 1
1
AC INPUT 2
2
3
ECP (+) VOLTAGE INPUT
GND
4
5
ZONE INPUT Z1/Z2
J1
7845i-GSM
BATTERY
ADEMCO
K14139
2-3
Table of Contents
loading

Table of Contents