Honeywell AlarmNet 7847i-E Installation And Setup Manual

Honeywell AlarmNet 7847i-E Installation And Setup Manual

Internet/intranet communication modules with remote services
Hide thumbs Also See for AlarmNet 7847i-E:
Table of Contents
I
n
I
n
K14175
11/07
A A A A
l l l l
a a a a
r r r r
m m m m
A A A A
l l l l
a a a a
r r r r
m m m m
t
e
r
n
e
t
/
I
n
t
r
a
t
e
r
n
e
t
/
I
n
t
r
a
   
   
N N N N
e e e e
t t t t
7 7 7 7
8 8 8 8
N N N N
e e e e
t t t t
7 7 7 7
8 8 8 8
n
e
t
C
o
m
m
u
n
e
t
C
o
m
m
u
Installation and Setup Guide
4 4 4 4
7 7 7 7
i i i i
/ / / /
7 7 7 7
8 8 8 8
4 4 4 4
4 4 4 4
7 7 7 7
i i i i
/ / / /
7 7 7 7
8 8 8 8
4 4 4 4
n
i
c
a
t
i
o
n
M
n
i
c
a
t
i
o
n
M
With Remote Services
Requires
Compass Version
1.5.8.54A
(or higher)
for IP Downloading
7 7 7 7
i i i i
- - - -
E E E E
7 7 7 7
i i i i
- - - -
E E E E
o
d
u
l
e
s
o
d
u
l
e
s
Table of Contents
loading

Summary of Contents for Honeywell AlarmNet 7847i-E

  • Page 1         A A A A l l l l a a a a r r r r m m m m N N N N e e e e t t t t 7 7 7 7 8 8 8 8 4 4 4 4...
  • Page 3: Table Of Contents

    Table of Contents • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • SECTION 1: General Information......................
  • Page 4 7847i/7847i-E Installation and Setup Guide Alternative Modes (Zone Trigger, 4204 and Two-4204) ..................3-9 Zone Trigger Mode ............................. 3-9 4204 Emulation Mode ..........................3-9 4204 Emulation Mode Options ........................3-9 Alternative Mode Programming ..........................3-10 Exiting Programming Mode ............................ 3-20 Setting Factory Defaults ............................
  • Page 5: Section 1: General Information

    Installs behind firewalls without compromising network security • Supports dynamic or static IP addressing • Quick connection to compatible Honeywell series control panels • Simple programming using a 7720P programming tool or AlarmNet Direct website • Reports fire, burg, and status messages via the Internet (or Intranet for 7847i-E) •...
  • Page 6: About Alarmnet-I Internet Application

    The communication devices use 256 bit AES (Rijndael) encryption (which is required for certain government installations). The AlarmNet-i AES Encryption Software Module Version 1.0 contained in the Honeywell products has NIST approval. Listings for this approval can be found at http://csrc.nist.gov/cryptval/aes/aesval.html...
  • Page 7: Remote Services

    Remote Access and Multi-Mode have not been evaluated by UL. Honeywell now offers a new series of web based services that provides consumers with the ability to communicate with their security system remotely in a number of ways. These new web services will allow users to: •...
  • Page 8: Module Supervision Features

    7847i/7847i-E Installation and Setup Guide • Each 4204 zone can be programmed for delayed reporting and restoral reporting • Reports are sent in ADEMCO High-Speed format Module Supervision Features The 7847i/7847i-E provides the following types of supervision and module fault detection: •...
  • Page 9: Section 2: Mounting And Wiring

    S E C T I O N Mounting and Wiring • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • In This Section Mounting the 7847i/7847i-E Power Connections and Options...
  • Page 10: Wiring The 7847I/7847I-E

    Setup Guide for the control panel you are using to see if it supports ECP communication. Connect the 7847i/7847i-E to a compatible Honeywell VISTA control panel's ECP terminals, in parallel with keypads and other peripheral devices, VIP module, etc. Wire length/gauge limitations are the same for the module as they are for keypads and other peripheral devices.
  • Page 11: Wiring For Zone Trigger Mode

    Section 2: Mounting and Wiring 4-WIRE CABLE (N4632-4) ECP DATA IN ECP DATA OUT LYNXR-I CONTROL PANEL 7847i / 7847i-E Figure 4. Wiring a LynxR-I for ECP Mode Wiring for Zone Trigger Mode To trip the zone on the 7847i/7847i-E in V+ trigger mode, the positive triggering voltage from the control panel must be within 2.0V-14V.
  • Page 12: Power Connections And Options

    7847i/7847i-E Installation and Setup Guide NOT USED NOT USED LRR / AAV 2K EOL TRIGGER RESISTOR ZONE INPUT Z1/Z2 LYNXR/LYNXR-EN CONTROL PANEL 7847i / 7847i-E Figure 6. Wiring the 7847i/7847i-E Zone 1 Input to a LynxR Trigger Output NOT USED NOT USED ECP (+) VOLTAGE INPUT 2K EOL...
  • Page 13: Initial Power-Up Sequence

    Section 2: Mounting and Wiring Xmit Shift 7720 PROGRAMMING TOOL BS / ESC N / Y Space Enter Shift ROUTER 7720P PROGRAM CONNECTOR TAMPER SWITCH/ IB SERVICE STATUS DISPLAY MODE AND STATUS RJ45 LED DISPLAY ETHERNET PORT NETWORK CONNECTIVITY LED DISPLAY MODE AND STATUS INDICATOR SWITCH 7847i-E-016-V0...
  • Page 14 7847i/7847i-E Installation and Setup Guide...
  • Page 15: Section 3: Programming The 7847I/7847I-E

    S E C T I O N Programming the 7847i/7847i-E • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • In This Section General Information Alternative Mode Programming...
  • Page 16: Using The Control Panel Programming Mode

    7847i/7847i-E Installation and Setup Guide Each key of the 7720P has two possible functions: a normal function and a Shift function. To perform a normal key function, simply press the desired key. To perform a Shift function, press the [shift] key, and then press the appropriate key. The prompts in this document reflect use of the 7720P Programming Tool.
  • Page 17 Section 3: Programming the 7847i/7847i-E NOTE: The default programming values for ECP mode are listed in each prompt below. Table 3: Programming a 7847i-E for ECP mode only. PROMPTS ENTRY OPTIONS DESCRIPTION [Y], [N] Enters programming mode. Strt Prog Mode? (Y/N)_ [0-9, A-F, N, S, If a password has been previously assigned, this...
  • Page 18 7847i/7847i-E Installation and Setup Guide The Multi-Mode address must match the address of a relay module enabled in the control panel (although you don’t actually connect a module). If using “2-4204-Sourced,” the address of the second module is automatically assigned the next device address after the first 4204.
  • Page 19 Section 3: Programming the 7847i/7847i-E PROMPTS ENTRY OPTIONS DESCRIPTION Enter the Central Station Port Number. [80] Second CS Port: NOTE: The CS Port number must match the "Listening (80) Port" question of the 7810iR-ent. • 30 Day Sets the supervision timing for the secondary internet IP2 Supervision receiver to send a test alarm if set to Daily or 30 Day, •...
  • Page 20 7847i/7847i-E Installation and Setup Guide NOTE: The Remote Access option is not available, and will not be displayed, when Private LAN is enabled on the 7847i-E. PROMPTS ENTRY OPTIONS DESCRIPTION Press [Y] to allow the end user to access their system Remote Access Y/N [Y], [N] via a website.
  • Page 21 Section 3: Programming the 7847i/7847i-E PROMPTS ENTRY OPTIONS DESCRIPTION Enter the time delay (01-99) in minutes before the [00-99] IP Flt Time 7847i/7847i-E notifies the control panel that there is (60 mins)_ loss of contact with the network, or enter 00 if you do not want the unit to alert the control panel of loss of contact with the network.
  • Page 22 7847i/7847i-E Installation and Setup Guide PROMPTS ENTRY OPTIONS DESCRIPTION [Y], [N] Enables alarm reporting for zone 7. Enable Zn7 Y/N If [N], skip to Prompt 47: "Use DHCP." (N)_ • (V+) Selects the triggering method for this zone input. Zn7 Trigger Type •...
  • Page 23: Ecp Status Codes

    The control panel must be configured to recognize one or two 4204 relay modules accordingly. On VISTA-32FB (or higher) control panels and First Alert equivalents, addresses 6 and 13 should not be used when the secondary 4204 is enabled. Messages are sent in Honeywell High-Speed format.
  • Page 24: Alternative Mode Programming

    7847i/7847i-E Installation and Setup Guide transmission of messages, and can be programmed to send reports only when a conditional zone is triggered (armed), (see Zone Input Options later in this section). In single 4204 mode, the unit supports up to four relay-zones. In two-4204 mode, the unit functions as two 4204 modules, supporting up to eight relay-zones.
  • Page 25 Cover tamper will send email event 8. All communication device system events (such as power loss, etc.) are still sent to AlarmNet. Events used to send email messages are defined on the Honeywell Total Connect web site, and must correspond to events triggering the hardwired zones.
  • Page 26 7847i/7847i-E Installation and Setup Guide Important Information Regarding Private LAN mode (7847i-E only). Prompts 12-18 apply only if Private LAN was selected in Prompt 11. Prompts 14-16 apply only if Prompt 14: Alarm Delivery is set to “Fail to CS IP2". 4204/ ZONE PROMPTS...
  • Page 27 Section 3: Programming the 7847i/7847i-E 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. Re-enter the 10-digit Installation Key to verify key. [0-9] Verify Inst. Key: **********_ If verification fails, “Verify NOT OK” will be ✔ ✔ displayed for one second and the display will return to the entry of the installation key.
  • Page 28 7847i/7847i-E Installation and Setup Guide 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. Must be programmed if using either the Remote ✔ Keypad Address [01-30] Access feature or Direct Wire downloading. Enter (28)_ the appropriate device address. NOTES: 1. This address must also be programmed as an alpha keypad in the control panel.
  • Page 29 Section 3: Programming the 7847i/7847i-E 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. ✔ ✔ Enter the time delay (01-99) in minutes before the [00-99] IP Flt Time 7847i/7847i-E notifies the control panel that there (60 mins)_ is loss of contact with the network, or enter 00 if you do not want the unit to alert the control panel of loss of contact with the network.
  • Page 30 7847i/7847i-E Installation and Setup Guide open collector, voltage trigger, NO, NC. Inverted Trigger: Zones can be programmed for inverted trigger, where the alarm and normal states of the zones are inverted; this can serve a fail-safe supervisory purpose for certain installations. Restore and Delayed Reports: Zone inputs can be programmed for restore reporting, and for delayed reporting (allowing time for the user to abort false alarms).
  • Page 31 Section 3: Programming the 7847i/7847i-E 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. ✔ ✔ Zone Trig: Enter the zone number to be used for open/close Open/Close Zone (arm/disarm) reports. (0)_ [3-7] This zone assignment must be unique from the 4204: [1-4] Telco Zone selected in Prompt 34.
  • Page 32 7847i/7847i-E Installation and Setup Guide 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. ✔ ✔ [Y], [N] Enables restore reporting for zone 3. Restore Zn3 Y/N (Y)_ ✔ ✔ [01-15] Defines the reporting delay in seconds for zone 3. Delay Zn3 (secs) (00) [00] = no delay ✔...
  • Page 33 Section 3: Programming the 7847i/7847i-E 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. ✔ ✔ [Y], [N] Enables restore reporting for zone 6. Restore Zn6 Y/N (Y)_ ✔ ✔ [01-15] Defines the reporting delay in seconds for zone 6. Delay Zn6 (secs) (00)_ [00] = no delay ✔...
  • Page 34: Exiting Programming Mode

    7847i/7847i-E Installation and Setup Guide 4204/ ZONE PROMPTS ENTRY OPTIONS DESCRIPTION 2-4204 TRIG. ✔ ✔ 12 digit: Enter the 4-part IP address assigned to the DNS DNS Serv IP Addr: xxx.xxx.xxx.xxx (Domain Name System) server. The four parts of 255.255.255.255_ [0.0.0.0.] = not the address must be separated by spaces used...
  • Page 35: Section 4: Registration

    S E C T I O N Registration • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • In This Section Registering the 7847i/7847i-E •...
  • Page 36: Using The Tamper Switch

    7847i/7847i-E Installation and Setup Guide Using the Tamper Switch Initiate the registration sequence by clicking the Tamper Switch three times. You can monitor the registration process by viewing the Status Display. The Message (yellow) LED and the Status (green) LED will blink slowly in unison while the registration is in progress.
  • Page 37 Section 4: Registration Possible Errors When Configured for AlarmNet-i Displayed if no response to the registration request is Registration BAD received. Timed Out Indicates the city, central station, or customer number Registration BAD for the Primary account(s) is not accepted. The ID Pri Sub ID BAD information was either entered in error, or the central station failed to pre-authorize programmed ID numbers...
  • Page 38: Register By Phone

    7847i/7847i-E Installation and Setup Guide If you entered an invalid PIN, the appropriate message Registration BAD is displayed depending on which account number is being replaced (see above for exact wording). The registration process is repeated. NOTE: Each attempt causes a substitution alarm to be sent to the central station.
  • Page 39: Section 5: Programmer Keyboard Commands

    S E C T I O N Programmer Keyboard Commands • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Programmer Keyboard Commands Programmer keyboard commands can be used to quickly view your Internet connectivity settings and options.
  • Page 40: System Status Displays

    5555555 5 status display includes: • Zone input status (1234567) - the numbers 1-7 represent the 7 mappings of the zone input, and follow Honeywell's ADEMCO high-speed format codes: 1 = New Event 5 = Normal X = Not Enabled •...
  • Page 41 Section 5: Programmer Keyboard Commands Reset the 7847i/7847i-E Reset CPU Y/N Pressing [N] returns to diagnostic mode (blank screen = enter next command or escape). Pressing [Y] resets the module (blank screen = reset complete). [↑ ↑ ↑ ↑ ] Registration Registering …...
  • Page 42 7847i/7847i-E Installation and Setup Guide...
  • Page 43: Section 6: Network Diagnostics

    S E C T I O N Network Diagnostics • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • In This Section Running Network Diagnostics on the Running Network Diagnostics on the 7847i-E...
  • Page 44: Possible Errors Running Network Diagnostics

    7847i/7847i-E Installation and Setup Guide The service at AlarmNet Control on Redir 2 is Redir 2 functioning. See below for possible errors that may Service OK occur at this stage of testing. The first step of the test traces the connection to Redir 3 Testing Redir 3 at AlarmNet Control.
  • Page 45: Running Network Diagnostics On The 7847I-E Using A Private Lan

    Section 6: Network Diagnostics Running Network Diagnostics on the 7847i-E using a Private LAN The network diagnostic process tests the integrity of the links between the 7847i-E and the 7810iR-ent to which it should report. To initiate the network diagnostics, press the [F] key on the 7720P. NOTE: The test is performed ONLY if a physical link is detected.
  • Page 46: Possible Errors Running Network Diagnostics Using A Private Lan

    7847i/7847i-E Installation and Setup Guide After a successful trace to CS IP 3, a test of the service Reached CSIP 3 at CS IP 1 is performed. That is, the first test Testing Service determines if a message can reach the 7810iR-ent; this test determines if the connection point (CSIP) at the 7810iR-ent knows what to do with the message once it receives it.
  • Page 47: Appendices

    Appendices • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Appendix A: Summary of LED Operation Status Display Operation The 7847i/7847i-E Status Display has three LEDs used to indicate message and device...
  • Page 48 7847i/7847i-E Installation and Setup Guide Table 6. Status Display Operation LED COLOR LED LABEL DESCRIPTION GREEN STATUS 7847i-E ON – 7847i/ is NOT registered with AlarmNet or 7810iR-ent if Private LAN is enabled. 7847i-E OFF – 7847i/ is registered with AlarmNet or 7810iR-ent if Private LAN is enabled.
  • Page 49: Network Connectivity Display

    Appendices Network Connectivity Display The Network Connectivity display can only be viewed with the cover removed. It is used as a visual indication of 7847i/7847i-E network activity. NETWORK COLLISION (YEL) LINK SPEED (GRN) ETHERNET LINK/ACTIVITY (GRN) NETWORK CONNECTIVITY LED DISPLAY 7847i-E-032-V0 Figure 15.
  • Page 50: Mode And Status Led Display

    7847i/7847i-E Installation and Setup Guide Mode and Status LED Display The Mode and Status LED Display consists of 4 LEDs. LED 1 (red LED on the left) will be off, LED 2 and 3 (yellow LEDs) indicate operation mode. LED 4 (1 green LED) displays Web connection status;...
  • Page 51: Appendix B: Central Station Messages

    Appendix B: Central Station Messages The following messages are sent by the 7847i/7847i-E module for the conditions listed below. Table 8. Central Station Messages ECP Mode ECP Mode Zone and 4204 Zone and 4204 Alarm Condition Alarm Code Restore Code Modes Modes Alarm Code...
  • Page 52 7847i/7847i-E Installation and Setup Guide...
  • Page 53: Appendix C: Ip Downloading

    Appendix C: IP Downloading General Information The 7847i/7847i-E can be used to provide high-speed up/downloading to Honeywell VISTA and LynxR-I control panels. This allows site maintenance independent of central station monitoring, and modification to sites through an Intranet or globally via the Internet.
  • Page 54 7847i/7847i-E Installation and Setup Guide Prior to IP up/downloading over an Intranet (Private LAN), setup of the Honeywell Compass Connect Server and Honeywell Compass downloader is required. Refer to the Compass Connect Server Installation and Setup Guide (K10178V1) and the Compass IP Downloading Supplement (K10441V1) for setup instructions.
  • Page 55: Appendix D: Glossary

    Appendix D: Glossary AES – Advanced Encryption Standard DHCP – Dynamic Host Configuration Protocol. Provides a mechanism for allocating IP addresses dynamically so that addresses can be reused when hosts no longer need them. DNS – Domain Name System. A distributed hierarchical naming system used to resolve domain names (e.g., www.yahoo.com) into numerical IP addresses (e.g., 204.17.25.1.).
  • Page 56 7847i/7847i-E Installation and Setup Guide...
  • Page 57 NOTES:...
  • Page 58 7847i/7847i-E Installation and Setup Guide NOTES:...
  • Page 59 NOTES:...
  • Page 60 7847i/7847i-E Installation and Setup Guide NOTES:...
  • Page 61 NOTES:...
  • Page 62 7847i/7847i-E Installation and Setup Guide NOTES:...
  • Page 63 7847i/ 7847i-E Summary of Connections STATUS LED MESSAGE LED FAULT LED 7720P PROGRAMMER PORT/ PANEL DOWNLOAD PORT TB 1 NOT USED MODE AND NOT USED STATUS 12V DC IN LED DISPLAY ZONE INPUT Z1/Z2 or ECP INPUT ZONE INPUT Z3 or ECP OUTPUT ZONE INPUT Z4 or NOT USED MODE AND STATUS...
  • Page 64 Honeywell factory service. Connection of any device(s) to a communicating bus of a Honeywell security system (e.g., keypad bus, polling loop) other than those manufactured or approved by Honeywell shall void this warranty.

This manual is also suitable for:

Alarmnet 7847i

Table of Contents