Wiring For Ecp, 4204 And Two-4204 Modes; Wiring For Zone Trigger Mode - Honeywell AlarmNet IGSMHS Installation And Setup Manual

Internet communication module
Table of Contents
IGSMHS Installation and Setup Guide

Wiring for ECP, 4204 and Two-4204 Modes

Most Honeywell control panels support ECP data communication. Check the Installation
and Setup Guide for the control panel you are using to see if it supports ECP communication.
Connect the IGSMHS to a compatible Honeywell VISTA control panel's ECP terminals, in
parallel with keypads and other peripheral devices such as RF receiver, VIP module, etc.
Wire length / gauge limitations are the same for the module as they are for keypads and other
peripheral devices. To wire the module for ECP or 4204 modes, see Figure 2-2 and make the
following connections:

Wiring for Zone Trigger Mode

To trip a zone using a positive trigger, the voltage level must be:
6V or greater = positive trigger. (Levels above +14V may cause damage to the unit.)
4V or less = restore.
To trip a zone using a negative trigger, the voltage level must be:
4V or less = negative trigger.
6V or greater = restore. (Levels above +14V may cause damage to the unit.)
NOTE: Remember to program the communications module zone for the desired trigger type.
Connect a wire from the triggering source (bell output, voltage trigger, etc.) of the control
panel to the zone input of the module, and connect a common ground between the module
and control panel. Examples of zone connections follow:
2-4
+12V AUX
GND
DATA OUT
DATA IN
VISTA CONTROL PANEL
Figure 2-2. Wiring a VISTA for ECP Mode or 4204 Modes
GND
+ TRIGGER
(VOLTAGE: 6 to 13V)
TRIGGERING DEVICE
Figure 2-3. Wiring Zone 1 Input for a Positive (+) Trigger
TRANSFORMER
RED
BLK
YEL
GRN
COMMUNICATIONS
MODULE
TRANSFORMER
TB1
AC INPUT 1
1
AC INPUT 2
2
GND
4
5
ZONE INPUT Z1/Z2
COMMUNICATIONS
MODULE
TB1
AC INPUT 1
1
AC INPUT 2
2
ECP (+) VOLTAGE INPUT
3
GND
4
5
ECP DATA IN
ECP DATA OUT
6
BATTERY
J1
BATTERY
J1
GSMV-005-V0