Chapter 6 Replacing the Consumables
6.3 Replacing the Pick Roller Unit
Replace the pick roller unit in following procedure.
1
Turn off the scanner and wait for at least 15 minutes.
For details, refer to
"1.3 Turning the Power ON/OFF" (page
2
Unplug the power cable.
3
Remove all documents from the ADF paper chute
(feeder).
4
Open the ADF cover.
For details, refer to
"1.4 Opening/Closing the ADF" (page
When the ADF cover is open, it might close
accidentally. Be careful not to get your
fingers caught.
5
Remove the pick roller unit.
1 Rotate the bushing until it clicks in the direction of the arrow.
Pick Roller
19).
Unit
Bushing
20).
2 Move it to the right while holding the busing, and remove it towards
you.