beautypg.com
Manuals
Brands
Daikin Manuals
Heat Pump
Altherma EHYKOMB33AA
Daikin Altherma EHYKOMB33AA Manuals
Manuals and User Guides for Daikin Altherma EHYKOMB33AA. We have
9
Daikin Altherma EHYKOMB33AA manuals available for free PDF download: Installer's Reference Manual, Service Manual, User Reference Manual, Installation And Operation Manual
Daikin Altherma EHYKOMB33AA Installer's Reference Manual (264 pages)
Hybrid heat pump
Brand:
Daikin
| Category:
Heat Pump
| Size: 13.02 MB
Table of Contents
Table of Contents
2
About the Product
6
About this Document
8
Meaning of Warnings and Symbols
8
Installer Reference Guide at a Glance
10
General Safety Precautions
12
For the Installer
12
General
12
Installation Site
13
Refrigerant - in Case of R410A or R32
14
Water
16
Electrical
16
Gas
18
Gas Exhaust
19
Local Legislation
19
Specific Installer Safety Instructions
21
About the Box
28
Outdoor Unit
28
To Unpack the Outdoor Unit
28
To Remove the Accessories from the Outdoor Unit
29
Indoor Unit
30
To Unpack the Indoor Unit
30
To Remove the Accessories from the Indoor Unit
31
Gas Boiler
31
To Unpack the Gas Boiler
31
To Remove the Accessories from the Gas Boiler
32
About the Units and Options
34
Identification
34
Identification Label: Outdoor Unit
34
Identification Label: Indoor Unit
35
Identification Label: Gas Boiler
35
Combining Units and Options
37
Possible Options for the Outdoor Unit
37
Possible Options for the Indoor Unit
38
Possible Options for the Gas Boiler
41
Possible Combinations of Indoor Unit and Outdoor Unit
46
Possible Combinations of Indoor Unit and Domestic Hot Water Tank
47
Unit Installation
48
Preparing the Installation Site
48
Installation Site Requirements of the Outdoor Unit
49
Additional Installation Site Requirements of the Outdoor Unit in Cold Climates
50
Installation Site Requirements of the Indoor Unit
51
Opening and Closing the Units
52
About Opening the Units
52
To Open the Outdoor Unit
52
To Open the Switch Box Cover of the Indoor Unit
53
To Open the Gas Boiler
54
To Open the Switch Box Cover of the Gas Boiler
54
To Close the Outdoor Unit
55
To Close the Indoor Unit
55
To Close the Gas Boiler
55
To Install the Gas Boiler Cover Plate
56
Mounting the Outdoor Unit
56
About Mounting the Outdoor Unit
56
Precautions When Mounting the Outdoor Unit
57
To Provide the Installation Structure
57
To Install the Outdoor Unit
59
To Provide Drainage
60
To Prevent the Outdoor Unit from Falling over
61
Mounting the Indoor Unit
62
About Mounting the Indoor Unit
62
Precautions When Mounting the Indoor Unit
62
To Install the Indoor Unit
62
Mounting the Gas Boiler
63
To Install the Gas Boiler
63
To Install the Condensate Trap
65
Connecting the Boiler to the Flue Gas System
66
To Change the Gas Boiler to 80/125 Concentric Connection
67
To Change the 60/100 Concentric Connection to a Dual Pipe Connection
68
Calculate the Total Piping Length
69
Appliance Categories and Pipe Lengths
70
Applicable Materials
74
Flue Pipe Position
75
Insulation of the Gas Exhaust and Air Intake
76
Fitting a Horizontal Flue System
76
Fitting a Vertical Flue System
77
Plume Management Kit
77
Flues in Voids
78
Flue Gas Materials (C63) Available on the Market
79
About Securing the Flue System
80
Condensate Pipe Work
81
Internal Connections
82
External Connections
83
Piping Installation
84
Preparing Refrigerant Piping
84
Refrigerant Piping Requirements
84
Refrigerant Piping Insulation
85
Connecting the Refrigerant Piping
85
About Connecting the Refrigerant Piping
85
Precautions When Connecting the Refrigerant Piping
86
Guidelines When Connecting the Refrigerant Piping
87
Pipe Bending Guidelines
87
To Flare the Pipe End
87
To Braze the Pipe End
88
Using the Stop Valve and Service Port
89
To Connect the Refrigerant Piping to the Outdoor Unit
90
To Connect the Refrigerant Piping to the Indoor Unit
91
Checking the Refrigerant Piping
91
About Checking the Refrigerant Piping
91
Precautions When Checking the Refrigerant Piping
92
To Check for Leaks
92
To Perform Vacuum Drying
92
To Insulate the Refrigerant Piping
93
Charging Refrigerant
94
About Charging Refrigerant
94
Precautions When Charging Refrigerant
95
To Determine the Additional Refrigerant Amount
95
To Determine the Complete Recharge Amount
95
To Charge Additional Refrigerant
95
To Fix the Fluorinated Greenhouse Gases Label
96
Preparing Water Piping
96
Water Circuit Requirements
96
Formula to Calculate the Expansion Vessel Pre-Pressure
99
To Check the Water Volume and Flow Rate
100
Changing the Pre-Pressure of the Expansion Vessel
102
To Check the Water Volume: Examples
103
Connecting Water Piping
103
About Connecting the Water Piping
103
Precautions When Connecting the Water Piping
103
Connecting the Water Piping of the Indoor Unit
104
Connecting the Water Piping of the Gas Boiler
105
To Fill the Space Heating Circuit
106
To Fill the Domestic Water Circuit of the Gas Boiler
107
To Fill the Domestic Hot Water Tank
107
To Insulate the Water Piping
107
Connecting the Gas Piping
108
To Connect the Gas Pipe
108
To Perform an Air Purge on the Gas Supply
108
Electrical Installation
110
About Connecting the Electrical Wiring
110
Precautions When Connecting the Electrical Wiring
111
Guidelines When Connecting the Electrical Wiring
111
Overview of Electrical Connections Except External Actuators
113
Overview of Electrical Connections for External and Internal Actuators
114
About Preferential Kwh Rate Power Supply
115
Connections to the Outdoor Unit
116
To Connect the Electrical Wiring to the Outdoor Unit
116
Connections to the Indoor Unit
117
To Connect the Electrical Wiring to the Indoor Unit
117
To Connect the Main Power Supply of the Indoor Unit
118
To Connect the Main Power Supply of the Gas Boiler
120
To Connect the Communication Cable between Gas Boiler and Indoor Unit
120
To Connect the User Interface
122
To Connect the Shut-Off Valve
124
To Connect the Electrical Meter
125
To Connect the Gas Meter
125
To Connect the Domestic Hot Water Pump
125
To Connect the Alarm Output
126
To Connect the Space Cooling/Heating ON/OFF Output
126
To Connect the Power Consumption Digital Inputs
127
To Connect the Safety Thermostat (Normally Closed Contact)
127
Configuration
129
Indoor Unit
129
Overview: Configuration
129
Basic Configuration
134
Advanced Configuration/Optimisation
154
Menu Structure: Overview User Settings
177
Menu Structure: Overview Installer Settings
179
Gas Boiler
180
Overview: Configuration
180
Basic Configuration
180
Operation
190
Overview: Operation
190
Heating
190
Domestic Hot Water
190
Flow Resistance Graph for Appliance Domestic Hot Water Circuit
191
Operation Modes
191
Commissioning
194
Overview: Commissioning
194
Precautions When Commissioning
195
Checklist before Commissioning
195
Checklist During Commissioning
196
To Check the Minimum Flow Rate
197
Air Purge Function
197
To Perform a Test Run
199
To Perform an Actuator Test Run
200
Underfloor Heating Screed Dryout
201
To Perform a Gas Pressure Test
204
To Perform a Test Run on the Gas Boiler
204
Hand-Over to the User
206
Maintenance and Service
207
Maintenance Safety Precautions
207
Opening the Indoor Unit
207
Checklist for Yearly Maintenance of the Outdoor Unit
207
Checklist for Yearly Maintenance of the Indoor Unit
208
To Disassemble the Gas Boiler
209
To Clean the Inside of the Gas Boiler
212
To Assemble the Gas Boiler
213
Troubleshooting
215
Overview: Troubleshooting
215
Precautions When Troubleshooting
215
Solving Problems Based on Symptoms
216
Symptom: the Unit Is NOT Heating or Cooling as Expected
216
Symptom: the Compressor Does NOT Start (Space Heating or Domestic Water Heating)
217
Symptom: the Pump Is Making Noise (Cavitation)
217
Symptom: the Pressure Relief Valve Opens
218
Symptom: the Water Pressure Relief Valve Leaks
218
Symptom: the Space Is NOT Sufficiently Heated at Low Outdoor Temperatures
218
Symptom: the Pressure at the Tapping Point Is Temporarily Unusually High
219
Daikin Altherma EHYKOMB33AA Installer's Reference Manual (252 pages)
Hybrid heat pump
Brand:
Daikin
| Category:
Heat Pump
| Size: 12.29 MB
Table of Contents
Table of Contents
2
1 General Safety Precautions
6
About the Documentation
6
Meaning of Warnings and Symbols
6
For the Installer
7
General
7
Installation Site
8
Refrigerant - in Case of R410A or R32
9
Water
11
Electrical
11
Gas
13
Gas Exhaust
14
Local Legislation
14
2 About the Product
16
3 About the Documentation
18
About this Document
18
Installer Reference Guide at a Glance
19
4 About the Box
20
Overview: about the Box
20
Outdoor Unit
20
To Unpack the Outdoor Unit
20
To Remove the Accessories from the Outdoor Unit
21
Indoor Unit
22
To Unpack the Indoor Unit
22
To Remove the Accessories from the Indoor Unit
23
Gas Boiler
23
To Unpack the Gas Boiler
23
To Remove the Accessories from the Gas Boiler
24
5 About the Units and Options
26
Overview: about the Units and Options
26
Identification
26
Identification Label: Outdoor Unit
26
Identification Label: Indoor Unit
27
Identification Label: Gas Boiler
27
Combining Units and Options
29
Possible Options for the Outdoor Unit
29
Possible Options for the Indoor Unit
30
Possible Options for the Gas Boiler
33
Possible Combinations of Indoor Unit and Outdoor Unit
38
Possible Combinations of Indoor Unit and Domestic Hot Water Tank
39
6 Preparation
40
Overview: Preparation
40
Preparing the Installation Site
40
Installation Site Requirements of the Outdoor Unit
40
Additional Installation Site Requirements of the Outdoor Unit in Cold Climates
42
Installation Site Requirements of the Indoor Unit
43
Preparing Refrigerant Piping
44
Refrigerant Piping Requirements
44
Refrigerant Piping Insulation
44
Preparing Water Piping
44
Water Circuit Requirements
45
Formula to Calculate the Expansion Vessel Pre-Pressure
48
To Check the Water Volume and Flow Rate
48
Changing the Pre-Pressure of the Expansion Vessel
50
To Check the Water Volume: Examples
51
Preparing Electrical Wiring
51
About Preparing Electrical Wiring
51
About Preferential Kwh Rate Power Supply
52
Overview of Electrical Connections Except External Actuators
53
Overview of Electrical Connections for External and Internal Actuators
54
7 Installation
56
Overview: Installation
56
Opening the Units
56
About Opening the Units
56
To Open the Outdoor Unit
56
To Open the Switch Box Cover of the Indoor Unit
57
To Open the Gas Boiler
58
To Open the Switch Box Cover of the Gas Boiler
58
Mounting the Outdoor Unit
59
About Mounting the Outdoor Unit
59
Precautions When Mounting the Outdoor Unit
59
To Provide the Installation Structure
59
To Install the Outdoor Unit
62
To Provide Drainage
62
To Prevent the Outdoor Unit from Falling over
63
Mounting the Indoor Unit
64
About Mounting the Indoor Unit
64
Precautions When Mounting the Indoor Unit
64
To Install the Indoor Unit
64
Mounting the Gas Boiler
66
To Install the Gas Boiler
66
To Install the Condensate Trap
67
Condensate Pipe Work
69
Internal Connections
69
External Connections
70
Connecting the Refrigerant Piping
70
About Connecting the Refrigerant Piping
70
Precautions When Connecting the Refrigerant Piping
71
Guidelines When Connecting the Refrigerant Piping
72
Pipe Bending Guidelines
72
To Flare the Pipe End
72
To Braze the Pipe End
73
Using the Stop Valve and Service Port
74
To Connect the Refrigerant Piping to the Outdoor Unit
75
To Connect the Refrigerant Piping to the Indoor Unit
76
Checking the Refrigerant Piping
76
About Checking the Refrigerant Piping
76
Precautions When Checking the Refrigerant Piping
77
To Check for Leaks
77
To Perform Vacuum Drying
78
Charging Refrigerant
79
About Charging Refrigerant
79
Precautions When Charging Refrigerant
80
To Determine the Additional Refrigerant Amount
80
To Determine the Complete Recharge Amount
80
To Charge Additional Refrigerant
80
To Fix the Fluorinated Greenhouse Gases Label
80
Connecting Water Piping
81
About Connecting the Water Piping
81
Precautions When Connecting the Water Piping
81
Connecting the Water Piping of the Indoor Unit
82
Connecting the Water Piping of the Gas Boiler
83
To Fill the Space Heating Circuit
84
To Fill the Domestic Water Circuit of the Gas Boiler
85
To Fill the Domestic Hot Water Tank
85
To Insulate the Water Piping
85
Connecting the Electrical Wiring
86
About Connecting the Electrical Wiring
86
Precautions When Connecting the Electrical Wiring
87
Guidelines When Connecting the Electrical Wiring
87
To Connect the Electrical Wiring to the Outdoor Unit
88
To Connect the Electrical Wiring to the Indoor Unit
88
To Connect the Main Power Supply of the Indoor Unit
90
To Connect the Main Power Supply of the Gas Boiler
91
To Connect the Communication Cable between Gas Boiler and Indoor Unit
92
To Connect the User Interface
94
To Connect the Shut-Off Valve
95
To Connect the Electrical Meter
96
To Connect the Gas Meter
97
To Connect the Domestic Hot Water Pump
97
To Connect the Alarm Output
97
To Connect the Space Cooling/Heating ON/OFF Output
98
To Connect the Power Consumption Digital Inputs
98
To Connect the Safety Thermostat (Normally Closed Contact)
99
Connecting the Gas Piping
100
To Connect the Gas Pipe
100
Connecting the Boiler to the Flue Gas System
101
To Change the Gas Boiler to 80/125 Concentric Connection
101
To Change the 60/100 Concentric Connection to a Dual Pipe Connection
102
Calculate the Total Piping Length
103
Appliance Categories and Pipe Lengths
104
Applicable Materials
108
Flue Pipe Position
109
Insulation of the Gas Exhaust and Air Intake
110
Fitting a Horizontal Flue System
110
Fitting a Vertical Flue System
111
Plume Management Kit
111
Flues in Voids
112
Flue Gas Materials (C63) Available on the Market
113
About Securing the Flue System
114
Finishing the Outdoor Unit Installation
115
To Finish the Outdoor Unit Installation
115
To Close the Outdoor Unit
116
Finishing the Indoor Unit Installation
116
To Close the Indoor Unit
116
Finishing the Gas Boiler Installation
116
To Perform an Air Purge on the Gas Supply
116
To Close the Gas Boiler
117
To Install the Cover Plate
118
8 Configuration
119
Indoor Unit
119
Overview: Configuration
119
Basic Configuration
124
Advanced Configuration/Optimisation
144
Menu Structure: Overview User Settings
167
Menu Structure: Overview Installer Settings
169
Gas Boiler
170
Overview: Configuration
170
Basic Configuration
170
9 Operation
180
Overview: Operation
180
Heating
180
Domestic Hot Water
180
Flow Resistance Graph for Appliance Domestic Hot Water Circuit
181
Operation Modes
181
10 Commissioning
183
Overview: Commissioning
183
Precautions When Commissioning
183
Checklist before Commissioning
184
Checklist During Commissioning
185
To Check the Minimum Flow Rate
185
Air Purge Function
186
To Perform a Test Run
188
To Perform an Actuator Test Run
189
Underfloor Heating Screed Dryout
190
To Perform a Gas Pressure Test
192
To Perform a Test Run on the Gas Boiler
193
11 Hand-Over to the User
195
12 Maintenance and Service
196
Overview: Maintenance and Service
196
Maintenance Safety Precautions
196
Opening the Indoor Unit
196
Checklist for Yearly Maintenance of the Outdoor Unit
196
Checklist for Yearly Maintenance of the Indoor Unit
197
To Disassemble the Gas Boiler
198
To Clean the Inside of the Gas Boiler
201
To Assemble the Gas Boiler
202
Daikin Altherma EHYKOMB33AA Service Manual (170 pages)
Brand:
Daikin
| Category:
Boiler
| Size: 9.41 MB
Table of Contents
Error Codes: Outdoor Units 1
4
Table of Contents
4
Overview of General Problems 4
55
Equipment Does Not Operate
56
Indoor Pump Operates, but Compressor Does Not
57
Cooling/Heating Operation Starts but Stops Immediately
59
After Unit Shuts Down, It Cannot be Restarted for a While
61
Equipment Produces Loud Noise or Shakes
63
The Unit Is Turned on but the Compressor Is Not Starting
67
Pump Is Making Noise (Cavitation)
68
The Water Pressure Relief Valve Opens
69
The Water Pressure Relief Valve Leaks
70
The User Interface Does Not Display Certain Screens
71
Domestic Hot Water Capacity Shortage at Low Outdoor Tem
72
Space Heating Capacity Shortage at Low Outdoor Tempera
73
Room Temperature Set Point IsnT Reached or Increases too
74
Error Codes: Outdoor Units
103
X93;E1 Outdoor Unit PCB Abnormality
103
X93;E3 Abnormal High Pressure (Detected by the HPS)
104
X93;E4 Actuation of Low Pressure Sensor
106
X93;E5 Compressor Motor Lock
109
X93;E7 Malfunction of Outdoor Unit Fan Motor
111
X93;E9 Malfunction of Electronic Expansion Valve
114
X93;F3 Malfunctioning in Discharge Pipe Temperature
117
X93;H3 Malfunctioning HPS System
119
X93;H9, J3, J5, J6, J7, J8 Thermistor or Related Abnormality (Outdoor Unit)
121
X93;J1 Malfunction of Pressure Sensor
122
X93;L1 Faulty Outdoor PC Board
124
X93;L4 Radiation Fin Temperature Increased
126
X93;L5 DC Output Overcurrent (Instantaneous)
128
X93;L8 DC Output Overcurrent (Instantaneous)
130
X93;L9 Stall Prevention (Time Lag)
132
Pcb)
134
X93;Lc Malfunction of Transmission System
134
X93;P1 Open Phase or Power Supply Voltage Imbalance
136
X93;P4 Malfunction of Radiator Fin Temperature Thermistor
137
X93;Pj Malfunction of Radiator Fin Temperature Thermistor
138
Error Codes: System Malfunctions
139
X93;U0 Gas Shortage (Malfunction)
139
X93;U2 Abnormal Power Supply Voltage
141
X93;U3 Underfloor Heating Screed Dry-Out Failure
143
X93;U4 Malfunction of Transmission between Hydro-Box and Outdoor Unit
144
Shortage
146
X93;Uf Malfunction of Transmission between Hydro-Box and Outdoor Unit or Gas
146
X93;U5 Malfunction of Transmission between Hydro-Box and Remote Controller
148
X93;Ua Indoor-Outdoor Combination Problem
149
Additional Checks for Troubleshooting
150
Check No.1 - Outdoor Unit: Checking the Installation Condition
150
Check No.2 - Outdoor Unit: Checking the Expansion Valve
151
Check No.3 - Checking the Thermistors
152
Check No.4 - Resistance Conversion Table (Ambient, Coil, Fin)
153
Check No.5 - Resistance Conversion Table (Discharge Pipe Sensor)
155
Check No.6 - Evaluation of Abnormal High Pressure
156
Check No.7 - Evaluation of Abnormal Low Pressure
157
Check No.8 - Clogged Points
158
Check No.10 - Outdoor Unit: Fan Speed Pulse
159
Check No.11 - Outdoor Unit: Check for Power Transistor
160
Check No.13 - Check for Inadequate Refrigerant
161
Check No.14 - Check for Excessive Refrigerant Charging
162
Check No.15 - Check for Factors Causing Wet Operation
163
Check No.16 - Troubleshooting Yonos para Inverter Pump (Only for EH/VB004-008)
164
Repair
165
Tips and Tricks
166
Maintenance
167
Maintenance
168
Maintenance Schedule
168
Daikin Altherma EHYKOMB33AA Installation And Operation Manual (44 pages)
hybrid heat pump – gas boiler
Brand:
Daikin
| Category:
Boiler
| Size: 5.16 MB
Table of Contents
1 About the Product
3
Table of Contents
3
2 About the Documentation
4
About this Document
4
3 General Safety Precautions
4
Meaning of Warnings and Symbols
4
For the Installer
5
General
5
Installation Site
5
Water
5
Electrical
6
Gas
6
Gas Exhaust
6
Local Legislation
6
4 About the Box
7
Gas Boiler
7
To Unpack the Gas Boiler
7
To Remove the Accessories from the Gas Boiler
8
5 About the Units and Options
8
Identification
8
Identification Label: Gas Boiler
8
Possible Combinations of Units and Options
8
List of Options for Gas Boiler
8
6 Preparation
10
Preparing the Gas Boiler Installation
10
7 Installation
11
Opening the Units
11
To Open the Gas Boiler
11
To Open the Switch Box Cover of the Gas Boiler
11
Mounting the Gas Boiler
11
To Install the Gas Boiler
11
To Install the Condensate Trap
12
Condensate Pipe Work
12
Internal Connections
13
External Connections
13
Connecting the Water Piping
13
Connecting the Water Piping of the Gas Boiler
13
To Fill the Space Heating Circuit
14
Connecting the Electrical Wiring
15
To Connect the Main Power Supply of the Gas Boiler
15
To Connect the Communication Cable between Gas Boiler and Indoor Unit
15
Connecting the Gas Piping
16
To Connect the Gas Pipe
16
Connecting the Boiler to the Flue Gas System
16
To Change the Gas Boiler to 80/125 Concentric Connection
16
To Change the 60/100 Concentric Connection to a Dual Pipe Connection
17
Calculate the Total Piping Length
17
Appliance Categories and Pipe Lengths
18
Applicable Materials
20
Flue Pipe Position
20
Insulation of the Gas Exhaust and Air Intake
21
Fitting a Horizontal Flue System
21
Fitting a Vertical Flue System
21
Plume Management Kit
21
Flues in Voids
22
Finishing the Gas Boiler Installation
22
To Close the Gas Boiler
22
To Install the Cover Plate
22
Daikin Altherma Hybrid Heat Pump - Gas Boiler Module
22
4P3530671A - 2013.10
22
8 Configuration
22
Gas Boiler
22
Overview: Configuration
22
Basic Configuration
23
9 Operation
27
Overview: Operation
27
Heating
27
Domestic Hot Water
27
Operation Modes
27
10 Commissioning
28
To Perform an Air Purge on the Gas Supply
28
To Perform a Test Run on the Gas Boiler
28
11 Maintenance and Service
29
Maintenance Safety Precautions
29
Opening the Gas Boiler
29
To Disassemble the Gas Boiler
29
To Clean the Inside of the Gas Boiler
30
To Assemble the Gas Boiler
31
12 Troubleshooting
31
General Guidelines
31
Solving Problems Based on Symptoms
32
Symptom: the Burner Does NOT Ignite
32
Symptom: the Burner Ignites Noisily
32
Symptom: the Burner Resonates
32
Symptom: no Space Heating by the Gas Boiler
32
Symptom: the Power Is Reduced
32
Symptom: Space Heating Does NOT Reach the Temperature
32
Symptom: no Domestic Hot Water
33
Symptom: Hot Water Does NOT Reach the Temperature
33
Solving Problems Based on Error Codes
33
Error Codes: Overview
33
Daikin Altherma EHYKOMB33AA Installation And Operation Manual (44 pages)
Brand:
Daikin
| Category:
Heat Pump
| Size: 6.92 MB
Table of Contents
1 About the Product
3
Table of Contents
3
2 About the Documentation
4
About this Document
4
3 General Safety Precautions
4
Meaning of Warnings and Symbols
4
For the Installer
5
General
5
Installation Site
5
Water
6
Electrical
6
Gas
7
Gas Exhaust
7
Local Legislation
7
4 About the Box
8
Gas Boiler
8
To Unpack the Gas Boiler
8
To Remove the Accessories from the Gas Boiler
8
5 About the Units and Options
9
Identification
9
Identification Label: Gas Boiler
9
Combining Units and Options
9
Possible Options for the Gas Boiler
9
6 Preparation
11
Preparing the Gas Boiler Installation
11
7 Installation
12
Opening the Units
12
To Open the Gas Boiler
12
To Open the Switch Box Cover of the Gas Boiler
12
Mounting the Gas Boiler
12
To Install the Gas Boiler
12
To Install the Condensate Trap
13
Condensate Pipe Work
13
Internal Connections
13
External Connections
14
Connecting Water Piping
14
Connecting the Water Piping of the Gas Boiler
14
Connecting the Electrical Wiring
15
To Connect the Main Power Supply of the Gas Boiler
15
To Connect the Communication Cable between Gas Boiler and Indoor Unit
15
Connecting the Gas Piping
16
To Connect the Gas Pipe
16
Connecting the Boiler to the Flue Gas System
17
To Change the Gas Boiler to 80/125 Concentric Connection
17
To Change the 60/100 Concentric Connection to a Dual Pipe Connection
17
Calculate the Total Piping Length
18
Appliance Categories and Pipe Lengths
18
Applicable Materials
20
Flue Pipe Position
21
Insulation of the Gas Exhaust and Air Intake
21
Fitting a Horizontal Flue System
21
Fitting a Vertical Flue System
22
Plume Management Kit
22
Flues in Voids
22
Flue Gas Materials (C63) Available on the Market
22
About Securing the Flue System
23
Finishing the Gas Boiler Installation
24
To Close the Gas Boiler
24
To Install the Cover Plate
25
8 Configuration
25
Gas Boiler
25
Overview: Configuration
25
Basic Configuration
25
9 Operation
30
Overview: Operation
30
Heating
30
Domestic Hot Water
30
Operation Modes
30
10 Commissioning
31
To Perform a Gas Pressure Test
31
To Perform a Test Run on the Gas Boiler
32
11 Maintenance and Service
32
Maintenance Safety Precautions
32
Opening the Gas Boiler
32
To Disassemble the Gas Boiler
32
To Clean the Inside of the Gas Boiler
34
To Assemble the Gas Boiler
34
12 Troubleshooting
35
General Guidelines
35
Precautions When Troubleshooting
35
Solving Problems Based on Symptoms
35
Symptom: the Burner Does NOT Ignite
35
Symptom: the Burner Ignites Noisily
35
Symptom: the Burner Resonates
35
Symptom: no Space Heating by the Gas Boiler
35
Symptom: the Power Is Reduced
35
Symptom: Space Heating Does NOT Reach the Temperature
36
Symptom: no Domestic Hot Water
36
Symptom: Hot Water Does NOT Reach the Temperature (no Tank Installed)
36
Solving Problems Based on Error Codes
36
Error Codes: Overview
36
Daikin Altherma EHYKOMB33AA User Reference Manual (60 pages)
Hybrid heat pump
Brand:
Daikin
| Category:
Heat Pump
| Size: 2.26 MB
Table of Contents
Table of Contents
2
General Safety Precautions
4
About the Documentation
4
Meaning of Warnings and Symbols
4
For the User
5
About this Document
7
About the System
8
Components in a Typical System Layout
8
Operation
9
Overview: Operation
9
The User Interface at a Glance
10
Buttons
10
Status Icons
11
Basic Usage
12
Using Home
12
Using the Menu Structure
12
Turning ON/OFF Controls
13
Space Heating/Cooling Control
14
About Space Heating/Cooling Control
14
Setting the Space Operation Mode
14
Determining Which Temperature Control You Are Using
16
Room Thermostat Control - about Room Thermostat Control
17
Room Thermostat Control - Using the Room Temperature Home
18
Room Thermostat Control - Using the Leaving Water Temperature Home
22
Leaving Water Temperature Control - about Leaving Water Temperature Control
24
Leaving Water Temperature Control - Using Leaving Water Temperature Control According to a Schedule
25
Leaving Water Temperature Control - Using Leaving Water Temperature Control NOT According to a Schedule
25
External Room Thermostat Control - about External Room Thermostat Control
25
External Room Thermostat Control - Using External Room Thermostat Control
26
Domestic Hot Water Control
26
About Domestic Hot Water Control
26
Instant DHW (no Tank Installed)
26
Tank
27
Advanced Usage
31
About Changing the User Permission Level
31
Using Quiet Mode
31
Using Holiday Mode
32
Reading out Information
35
Configuring Date, Time, Units of Measurement, Contrast and Backlight
36
Configuring User Profile and Home
36
Locking and Unlocking Buttons and Functions
37
Preset Values and Schedules
38
Using Preset Values
38
Using and Programming Schedules
39
Schedules: Example
40
Predefined Schedules: Room Temperature + Leaving Water Temperature (Main)
41
Predefined Schedules: Leaving Water Temperature (Additional)
42
Predefined Schedules: DHW Tank Temperature
42
Weather Dependent Operation
43
To Set the Weather Dependent Settings
43
Menu Structure: Overview User Settings
44
Installer Settings: Tables to be Filled in by Installer
45
Quick Wizard
45
Space Heating/Cooling Control
46
Domestic Hot Water Control [A.4]
46
Contact/Helpdesk Number [6.3.2]
46
Setting the Energy Prices
47
To Set the Gas Price
47
To Set the Electricity Price
47
To Set the Electricity Price Schedule Timer
48
About Energy Prices in Case of an Incentive Per Kwh Renewable Energy
48
To Set the Gas Price in Case of an Incentive Per Kwh Renewable Energy
48
To Set the Electricity Price in Case of an Incentive Per Kwh Renewable Energy
48
Example
48
Energy Visualisation
50
To View the Energy Statistics
50
Energy Saving Tips
51
Maintenance and Service
52
Overview: Maintenance and Service
52
To Find the Contact/Helpdesk Number
52
Daikin Altherma EHYKOMB33AA User Reference Manual (56 pages)
Brand:
Daikin
| Category:
Water Pump
| Size: 1.77 MB
Table of Contents
Table of Contents
2
1 General Safety Precautions
4
About the Documentation
4
Meaning of Warnings and Symbols
4
For the User
5
2 About this Document
7
3 About the System
8
Components in a Typical System Layout
8
4 Operation
9
Overview: Operation
9
The User Interface at a Glance
10
Buttons
10
Status Icons
11
Basic Usage
12
Using Home
12
Using the Menu Structure
12
Turning ON/OFF Controls
13
Space Heating Control
14
Determining Which Temperature Control You Are Using
14
Room Thermostat Control - about Room Thermostat Control
15
Room Thermostat Control - Using the Room Temperature Home
16
Room Thermostat Control - Using the Leaving Water Temperature Home
20
External Room Thermostat Control - about External Room Thermostat Control
22
External Room Thermostat Control - Using External Room Thermostat Control
22
Domestic Hot Water Control
22
About Domestic Hot Water Control
23
Instant DHW (no Tank Installed)
23
Tank
23
Advanced Usage
27
About Changing the User Permission Level
27
Using Quiet Mode
27
Using Holiday Mode
28
Reading out Information
31
Configuring Date, Time, Units of Measurement, Contrast and Backlight
32
Configuring User Profile and Home
32
Locking and Unlocking Buttons and Functions
33
Preset Values and Schedules
34
Using Preset Values
34
Using and Programming Schedules
35
Schedules: Example
36
Predefined Schedules: Room Temperature + Leaving Water Temperature (Main)
37
Predefined Schedules: DHW Tank Temperature
37
Weather Dependent Operation
38
To Set the Weather Dependent Settings
38
Menu Structure: Overview User Settings
40
Installer Settings: Tables to be Filled in by Installer
41
Quick Wizard
41
Space Heating Control
41
Domestic Hot Water Control [A.4]
42
Contact/Helpdesk Number [6.3.2]
42
5 Setting the Energy Prices
43
To Set the Gas Price
43
To Set the Electricity Price
43
To Set the Electricity Price Schedule Timer
44
About Energy Prices in Case of an Incentive Per Kwh Renewable Energy
44
To Set the Gas Price in Case of an Incentive Per Kwh Renewable Energy
44
To Set the Electricity Price in Case of an Incentive Per Kwh Renewable Energy
44
Example
44
6 Energy Saving Tips
46
7 Maintenance and Service
47
Overview: Maintenance and Service
47
To Find the Contact/Helpdesk Number
48
Daikin Altherma EHYKOMB33AA User Reference Manual (28 pages)
Brand:
Daikin
| Category:
Heat Pump
| Size: 2.31 MB
Table of Contents
Table of Contents
2
General Safety Precautions
2
About the Documentation
2
Meaning of Warnings and Symbols
2
For the User
3
About this Document
3
About the System
4
Components in a Typical System Layout
4
Operation
4
Overview: Operation
4
The User Interface at a Glance
4
Buttons
4
Status Icons
5
Basic Usage
5
Using Home
5
Using the Menu Structure
5
Turning ON/OFF Controls
6
Space Heating/Cooling Control
6
About Space Heating/Cooling Control
6
Setting the Space Operation Mode
6
Determining Which Temperature Control You Are Using
7
Room Thermostat Control - about Room Thermostat Control
7
Room Thermostat Control - Using the Room Temperature Home Page
8
Room Thermostat Control - Using the Leaving Water Temperature Home
9
Leaving Water Temperature Control - about Leaving Water Temperature Control
10
Leaving Water Temperature Control - Using Leaving Water Temperature Control According to a Schedule
10
Leaving Water Temperature Control - Using Leaving Water Temperature Control NOT According to a Schedule
11
External Room Thermostat Control - about External Room Thermostat Control
11
External Room Thermostat Control - Using External Room Thermostat Control
11
Domestic Hot Water Control
11
About Domestic Hot Water Control
11
Instant DHW (no Tank Installed)
11
Tank
12
Advanced Usage
13
About Changing the User Permission Level
13
Using Quiet Mode
13
Using Holiday Mode
14
Reading out Information
15
Configuring Date, Time, Units of Measurement, Contrast and Backlight
15
Configuring User Profile and Home
16
Locking and Unlocking Buttons and Functions
16
Preset Values and Schedules
16
Using Preset Values
16
Using and Programming Schedules
17
Schedules: Example
17
Predefined Schedules: Room Temperature + Leaving Water Temperature (Main)
18
Predefined Schedules: Leaving Water Temperature (Additional)
18
Predefined Schedules: DHW Tank Temperature
18
Weather Dependent Operation
18
To Set the Weather Dependent Settings
18
Menu Structure: Overview User Settings
20
Installer Settings: Tables to be Filled in by Installer
21
Quick Wizard
21
Space Heating/Cooling Control
21
Domestic Hot Water Control [A.4]
21
Contact/Helpdesk Number [6.3.2]
21
Setting the Energy Prices
21
To Set the Gas Price
22
To Set the Electricity Price
22
To Set the Electricity Price Schedule Timer
22
About Energy Prices in Case of an Incentive Per Kwh Renewable Energy
22
To Set the Gas Price in Case of an Incentive Per Kwh Renewable Energy
22
To Set the Electricity Price in Case of an Incentive Per Kwh Renewable Energy
22
Example
22
Energy Visualisation
22
To View the Energy Statistics
22
Energy Saving Tips
23
Maintenance and Service
23
Overview: Maintenance and Service
23
To Find the Contact/Helpdesk Number
23
Troubleshooting
23
Daikin Altherma EHYKOMB33AA User Reference Manual (24 pages)
Altherma hybrid heat pump
Brand:
Daikin
| Category:
Heat Pump
| Size: 0.84 MB
Table of Contents
1 General Safety Precautions
2
Table of Contents
2
About the Documentation
2
Meaning of Warnings and Symbols
2
2 About this Document
3
For the User
3
3 About the System
3
Components in a Typical System Layout
3
4 Operation
4
Overview: Operation
4
The User Interface at a Glance
4
Buttons
4
Status Icons
5
Basic Usage
5
Using the Menu Structure
5
Turning ON/OFF Controls
6
Space Heating/Cooling Control
6
About Space Heating/Cooling Control
6
Setting the Space Operation Mode
6
Controlling the Temperature
7
Domestic Hot Water Control
10
About Domestic Hot Water Control
10
Instant DHW (no Tank Installed)
11
Tank
11
Advanced Usage
13
Using Quiet Mode
13
Using Holiday Mode
13
Reading out Information
15
Configuring Date, Time, Units of Measurement, Contrast and Backlight
15
Locking and Unlocking Buttons and Functions
16
Preset Values and Schedules
16
Using Preset Values
16
Using and Programming Schedules
16
Schedules: Example
17
Predefined Schedules: Room Temperature + Leaving Water Temperature (Main)
18
Predefined Schedules: Leaving Water Temperature (Additional)
18
Predefined Schedules: DHW Tank Temperature
18
Menu Structure: Overview
19
Installer Settings: Tables to be Filled in by Installer
20
Quick Wizard
20
Space Heating/Cooling Control
20
Domestic Hot Water Control [A.4]
20
Contact/Helpdesk Number [6.3.2]
20
5 Setting the Energy Prices
20
To Set the Gas Price
20
To Set the Electricity Price
20
To Set the Electricity Price Schedule Timer
21
6 Energy Visualisation
21
To View the Energy Statistics
21
7 Energy Saving Tips
21
8 Maintenance and Service
21
Overview: Maintenance and Service
21
To Find the Contact/Helpdesk Number
21
Related Products
Daikin EHYKOMB33A
Daikin EHYHBH05AA
Daikin EHYHBH08AA
Daikin EHYHBX08AA
Daikin Altherma EHYHBH05AF
Daikin Altherma EHYHBH/X08AF
Daikin Altherma H Hybrid EHY2KOMB-A
Daikin Altherma EHYHBX-AV32 Series
Daikin Altherma EHYHBH08AF
Daikin Altherma EHYHBX08AF
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals