Gas Boiler; Overview: Configuration; Basic Configuration - Daikin Altherma EVLQ05+08CA Installer's Reference Manual

Hybrid heat pump
Hide thumbs Also See for Altherma EVLQ05+08CA:
Table of Contents
8
|
Configuration

8.2 Gas boiler

8.2.1 Overview: Configuration

8.2.2 Basic configuration

To turn on/off the gas boiler
Domestic hot water comfort function
To reset the gas boiler
Installer reference guide
170
1
3 4
a
Read out
1 On/OFF
2 Main display
3 Space heating operation
4 Domestic hot water operation
5 Domestic hot water comfort
function eco
6 Domestic hot water comfort
function on (continuous)
7 Service display
8 Flashes to indicate a fault
1 Push the button.
Result: The green LED above the button will light up when the boiler is ON.
When the gas boiler is OFF, is displayed on the service display to indicate that the
power is ON. In this mode, the pressure in the space heating installation will also
be displayed on the main display (bar).
Not applicable for Switzerland
This function can be operated with the domestic hot water comfort key ( ). The
following functions are available:
On: The LED lights up. The domestic hot water comfort function is switched on.
The heat exchanger will be kept on temperature to assure instant delivery of hot
water.
Eco: The
LED lights up. The domestic hot water comfort function is self-
learning. The appliance will learn to adapt to the pattern of use of hot tap water.
For example: the temperature of the heat exchanger will NOT be maintained
during the night or in case of long absence.
Off: Both LED's are OFF. The temperature of the heat exchanger is NOT
maintained. For example: It will take a while to deliver hot water to the hot water
taps. If there is no need for immediate hot water delivery, the domestic hot
water comfort function can be turned off.
INFORMATION
Resetting is only possible when an error occurs.
2
5 6
b
c
d
EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
7
8
e
f
Operation
a On/OFF button
b One single room
c
button
d
button
e Service button
f Reset button
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
Table of Contents