9.1.3 Overview of electrical connections except external actuators

EVLQ05+08CA + EHYHBH05A + EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
Normal power supply
a Normal power supply
b Preferential kWh rate power supply
1 Power supply for outdoor unit
2 Power supply and interconnection cable to indoor unit
3 Power supply for gas boiler
4 Preferential kWh rate power supply (voltage free contact)
5 Normal kWh rate power supply (to power the indoor unit PCB in the event of power
supply interruption of the preferential kWh rate power supply)
The following applies ONLY for the French market: "Bleu Ciel tarif"
In France there is a preferential kWh rate called "Bleu Ciel tarif". This rate divides
the days of the year in:
blue days (preferential electricity rate, ideal for heat pump operation),
white days (ideal for heat pump and hybrid operation),
and red days (high electricity rate, boiler operation preferred).
It is recommended to use the preferential kWh rate power supply contact (4) to
force boiler operation during red days. Note that sometimes it is required to set
the meter on such that, it only closes the contact on red days. Please refer to the
manual of the applicable meter.
The indoor unit and gas boiler are NOT compatible with other combinations of
contacts (e.g., closed contacts on white/blue days). Connect the indoor unit and
gas boiler as follows: see illustration in column "Power supply is NOT interrupted"
in the table above.
a Normal power supply
Preferential kWh rate power supply
Power supply is NOT
interrupted
b
0
0
58 0
1 5 0
3
1
4
2
During preferential kWh
rate power supply
activation, power supply
is NOT interrupted. The
outdoor unit is turned off
by the control. The gas
boiler can still operate.
Remark: The electricity
company must always
allow the power
consumption of the
indoor unit.
9
Electrical installation
|
Power supply is
interrupted
a
b
0
0
0
0
58 0
58 0
1 5 0
1 5 0
5
3
4
2
During preferential kWh
rate power supply
activation, power supply
is interrupted
immediately or after
some time by the
electricity company. In
this case, the indoor unit
must be powered by a
separate normal power
supply. The outdoor unit
CANNOT operate, but the
gas boiler can operate.