4.6.3
Reading out information
About reading out information
The amount of information you can read out in the menu structure
([6]: Information) depends on your user permission level:
▪ End user (= default)
▪ Adv. end user: You can read out more information.
To switch between user permission levels (End user and
Advanced end user)
1 Go to [6] or any of its submenus:
2 Press
for more than 4 seconds.
Result: The user permission level switches to Adv. end user.
Additional information is displayed and "+" is added to the menu
title.
3 If you do NOT press any button for more than 1 hour or press
again for more than 4 seconds, the user permission level
switches back to End user.
To read out information
Go to [6]:
> Information.
Possible readout information
If user permission level = End user, you can read out the following
information:
In menu...
[6.1] Sensor information
[6.2] Energy metering
[6.3] Error handling
[6.4] User permission level
If user permission level = Adv. end user, you can read out the
following additional information:
In menu...
[6.1] Sensor information
[6.2] Energy metering
[6.5] Actuators
[6.6] Operation modes
[6.7] Running hours
[6.8] Version
EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P3556321 – 2013.05
> Information.
You can read out...
Room, tank or DHW, and outside
temperature.
Produced energy, consumed
electricity, and consumed gas.
Error history and contact/
helpdesk number.
Current user permission level.
You can read out...
Room, tank or DHW, outside,
and leaving water temperature.
(If applicable)
Produced energy, consumed
electricity, and consumed gas.
Status/mode of each actuator.
Example: Domestic hot water
pump ON/OFF.
Current operation mode.
Example: Defrost/oil return
mode.
Running hours of the system.
Version information about the
system.
4.6.4
Configuring date, time, units of
measurement, contrast and backlight
To configure time and date
Go to [1]:
> Set time/date.
To configure units of measurement
Go to [7.6]:
> User settings > Unit of measurement.
Possible units of measurement settings
Setting
Decimal point
Temperature
Produced energy
Flow
Consumed gas
To configure the contrast of the user interface
Go to [7.1.1]:
> User settings > Display > Contrast.
To configure the backlit LCD time of the user interface
Go to [7.1.2]:
> User settings > Display > Backlit LCD time.
4.6.5
Configuring user profile and home pages
To set a user profile
1 Go to [7.1.3]:
> User settings > Display > User profile.
2 Select a user profile and press
Possible user profiles
If user profile = Detailed, you can see and do more on the home
pages.
User profile
Basic
20.0°C
Actual temperature
Detailed
20.0°C
Actual temperature
Scheduled
Tue
17:30
4 Operation
Possible units of measurement
▪ Dot
▪ Comma
▪ °C
▪ °F
▪ kWh
▪ MBtu
▪ l/min
▪ GPM
3
▪ m
▪ kWh
.
Example
Mon
15:20
Room
Mon
15:20
Room
User reference guide