4.4.2 Room thermostat control - About room thermostat control

CHYHBH05+08AF + EHYKOMB33AA
Daikin Altherma R Hybrid
4P471762-1B – 2020.10
Typical additional leaving water temperature home page:
User profile = Basic
45°C
Desired temperature
2 Check the following:
If...
Room temperature is listed
under:
[6.1]:
> Information >
Sensor information
Thermostat main A is listed
under:
[6.5]:
> Information >
Actuators
3 Only for room thermostat control: Go to the main leaving water temperature
home page (LWT main) and check the following:
Is displayed next to
the set point?
Yes
No
Room thermostat control means that you control the following:
Room temperature of the main zone
Leaving water temperature of the main zone
Room temperature of the main zone
To control the room temperature of the main zone, you can do the following:
You can...
Read out the actual and desired room temperature.
Temporarily overrule the room temperature
schedule.
User profile = Detailed
Mon
15:20
45°C
LWT add
Desired temperature
Mon
17:30
Then the temperature control is...
Main zone
Room thermostat
control.
Go to next step to
check if leaving water
set point and room
temperature set point
are linked.
External room thermostat control.
Then leaving water set point and room
temperature set point are...
NOT linked.
You can set the leaving water set point on the home
page.
Linked by their preset values. You can set the preset
values in the menu structure.
4
Operation
|
Mon
15:20
LWT add
Additional zone (if
any)
External room
thermostat control.
Location
Room temperature home
page
User reference guide