CC-Link IE Field Network Basic
CC-Link extended setting (Pr. 544)
Use this parameter to select the function of the remote registers for the CC-Link IE Field Network Basic.
Pr. 544
0 (initial setting)
1
12
14
18
Tab. 6-141: Settings of Pr. 544
Frequency command with sign (Pr. 541)
● The start command (forward/reverse rotation) can be inverted by adding a plus or minus sign to
the value of the frequency command sent through the CC-Link IE Field Network Basic.
● The Pr. 541 "Frequency command sign selection setting" is applied to the frequency command
from RWw1. (Refer to page 6-358.)
Pr. 541
0
1
Tab. 6-142: Function of the sign selection with Pr. 541
● Relationship between the start command and sign (Pr. 541="1")
Start command
Forward rotation
Reverse rotation
Tab. 6-143: Influence of the sign on the rotation direction
NOTES
When Pr. 541 = 1 (with sign)
● When E²PROM write is specified with the RYE, write mode error (error code H01) will occur.
● When concurrent execution of both RYD and RYE is enabled (when a value other than 0 is set in
Pr. 544) and both RYD and RYE are turned on, RYD has precedence.
● When power is turned on (inverter reset), the initial setting status of the sign bit is "positive"
and the set frequency is "0 Hz". (The motor does not operate at the frequency set before turn-
ing OFF the power (inverter reset).)
● When set frequency is written with the instruction code of HED and HEE, the sign of the fre-
quency command is not changed.
6 - 350
Description
Compatible with CC-Link Ver.1
Compatible with CC-Link Ver.1
Compatible with the double setting of CC-Link Ver.2
Compatible with the quadruple setting of CC-Link Ver.2
Compatible with the octuple setting of CC-Link Ver.2
Sign
Setting range
Not used
0 to 40000
With
–32768 to 32767 (two's complement)
Sign of the frequency command
+
+
Actual frequency command
0 to 400.00 Hz
-327.68 to 327.67 Hz
Actual run command
Forward rotation
Reverse rotation
Reverse rotation
Forward rotation
Parameter
Refer to page
6-351
6-352
6-353
6-354
6-355

Hide quick links: