Table 122 - Fault Code Summary
(1) (2)
Fault Code Type
Description
Standard runtime axis exceptions. The exception can apply to an individual axis or to
FLT Sxx
all axes.
Manufacturer-specific runtime axis exception. The exception can apply to an individual
FLT Mxx
axis or to all axes.
INIT FLT Sxx
Exceptions that prevent normal operation and occur during the initialization process.
INIT FLT Mxx
Exceptions that can prevent normal operation of the drive module and apply to the
NODE FLTxx
entire module and affect all axes.
Exceptions that can prevent normal operation of the drive module, but do not result in
NODE ALARM xx
any action other than reporting the alarm to the controller.
INHIBIT Sxx
Conditions that prevent normal operation and indicate the drive module is prevented
from being enabled.
INHIBIT Mxx
ALARM Sxx
An underlying exception condition that does not result in any action other than
reporting the alarm to the controller.
ALARM Mxx
(3)
SAFE FLTxx
Exception generated by a fault condition detected in the safety function.
(1) Sxx refers to Standard exceptions.
(2) Mxx refers to Manufacturer-specific exceptions.
(3) For troubleshooting 2198-xxxx-ERS3 inverter SAFE FLT fault codes, refer to
page 316
(hardwired safety) or
refer to the Kinetix 5700 Safe Monitor Functions Safety Reference Manual, publication 2198-RM001.
TIP Fault codes triggered by conditions that fall outside factory set limits are identified by
FL at the end of the display message. For example, FLT S07 – MTR OVERLOAD FL.
Fault codes triggered by conditions that fall outside user set limits are identified by UL
at the end of the display message. For example, FLT S08 – MTR OVERLOAD UL.

Fault Codes

For fault code descriptions and possible solutions, see the Kinetix 5700 Fault
Codes.xlsx file attached to this publication. For more information about the
file, see
Access the Attachments

SAFE FLT Fault Codes

For troubleshooting 2198-xxxx-ERS4 inverter SAFE FLT fault codes, refer to
the Kinetix 5700 Safe Monitor Functions Safety Reference Manual,
publication 2198-RM001.
Rockwell Automation Publication 2198-UM002G-EN-P - February 2019
Troubleshoot the Kinetix 5700 Drive System
Troubleshoot the Safe Torque-off Function
page 329
(integrated safety). For troubleshooting 2198-xxxx-ERS4 inverter SAFE FLT fault codes,
on
page
13.
Chapter 7
on
277