Allen-Bradley Kinetix 5700 Installation Instructions Manual

Capacitor module and extension module
Hide thumbs Also See for Kinetix 5700:
Installation Instructions
Original Instructions
Kinetix 5700 Capacitor Module and
Extension Module
Catalog Numbers 2198-CAPMOD-2240, 2198-CAPMOD-DCBUS-IO
Topic

Summary of Changes

This manual contains new and updated information as indicated in the following table.
Topic
Updated the mounting and installation information consistent with the Bulletin 2198 DC-bus conditioner
module and introduced all three modules as accessory modules.
Updated the external DC-bus current values as 104 A systems and 208 A systems, maximum.
Replaced the extension module in the extended (208 A) system example with a DC-bus conditioner module.
Added information to make clear how to obtain flexible bus-bars.
Page
1
2
2
3
7
9
14
Page
Throughout
4
5
6
9
11
2, 12
Table of Contents
loading

Summary of Contents for Allen-Bradley Kinetix 5700

  • Page 1: Table Of Contents

    Installation Instructions Original Instructions Kinetix 5700 Capacitor Module and Extension Module Catalog Numbers 2198-CAPMOD-2240, 2198-CAPMOD-DCBUS-IO Topic Page Summary of Changes About the Capacitor Module and Extension Module Before You Begin Install the Capacitor Module and Extension Module Connector Data Wiring Requirements...
  • Page 2: About The Capacitor Module And Extension Module

    2198-DCBUSCOND-RP312 DC-bus conditioner module are also referred to as Kinetix® 5700 accessory modules. Accessory modules can be used in any Kinetix 5700 drive system configurations with DC-bus power supplies, regenerative bus supplies, and 8720MC-RPS power supplies. Accessory Module Description Cat.
  • Page 3: Install The Capacitor Module And Extension Module

    SHOCK HAZARD: To avoid the hazard of electrical shock, perform all mounting and wiring of the Kinetix 5700 drive modules prior to applying power. Once power is applied, and then removed, you must wait 5 minutes and verify that the DC-bus voltage has discharged before servicing.
  • Page 4: Also, Updated The Descriptive Text Explaining When The Accessory Modules Are Required

    For extended 104 A drive systems, the 2198-DCBUSCOND-RP312 DC-bus conditioner modules can be removed from Cluster 1 and Cluster 2 if they are not required to help protect system components. Kinetix 5700 Drive System Example with Extended (208 A) Drive Cluster DC-bus Single-axis...
  • Page 5: Replaced The Extension Module In The 8720Mc-Rps System Example With A Dc-Bus Conditioner Module. Also, Updated The Descriptive Text Explaining When The Accessory Modules Are Required

    The only limit to the number of capacitor modules in a system is the amount of total capacitance of the system. See the Kinetix 5700 Servo Drives User Manual, publication 2198-UM002, to determine the maximum system capacitance for your selected DC-bus power supply or regenerative bus supply.
  • Page 6: Added Dimensions To The M8 Dc-Bus Stud Connections On Accessory Modules To Help Size Lugs, If Required

    Kinetix 5700 Capacitor Module and Extension Module Product Dimensions Refer to the Kinetix 5700 Servo Drives User Manual, publication 2198-UM002, for system-wide drill hole specifications. Capacitor Module and Extension Module Dimensions Dimensions are in mm (in.) 29.5 (1.16) (2.16) 40.6 31.9...
  • Page 7: Connector Data

    Kinetix 5700 Capacitor Module and Extension Module Connector Data Lug spacers are needed only when wiring both external DC-bus and active shunt connections to the lug studs. Two types of lug covers are provided, one for systems with external DC-bus or active shunt wires attached and one without.
  • Page 8 Kinetix 5700 Capacitor Module and Extension Module Extension Module Features and Indicators 5700 2198-CAPMOD-DCBUS-IO Extension Module (side view, lug cover removed) 2198-CAPMOD-DCBUS-IO Extension Module (front view) 2198-CAPMOD-DCBUS-IO Extension Module (top views) Item Description Item Description Ground lug DC– M8 stud (external DC-bus)
  • Page 9: Wiring Requirements

    Kinetix 5700 Capacitor Module and Extension Module Control Input Power (CP) Connector Pinout CP Pin Description Signal 24V power supply, customer-supplied 24V+ 24V common 24V– Module Status (MS) Connector Pinout MS Pin Description Signal Module status output Wiring Requirements IMPORTANT The National Electrical Code and local electrical codes take precedence over the values and methods provided.
  • Page 10 Kinetix 5700 Capacitor Module and Extension Module Wire an External Active Shunt Active shunts wire to the DC-bus studs. The capacitor module and extension module are equipped with spacers that slide onto the M8 studs. When the system configuration includes external DC-bus and active shunt connections, external DC-bus connections are made below the spacer and active shunt connections are made above the spacer.
  • Page 11: Updated The Compatible Active Shunt Specifications Information

    Kinetix 5700 Capacitor Module and Extension Module Rockwell Automation Publication 2198-IN008D-EN-P - February 2019...
  • Page 12 DC-bus conditioner module (1) For flexible bus-bars, order either 2198-KITCON-CAPMOD2240 or 2198-KITCON-DCBUSCOND connector set. See the Kinetix 5700 Servo Drives User Manual, publication 2198-UM002, for detailed information on wiring, applying power, and troubleshooting accessory modules. Rockwell Automation Publication 2198-IN008D-EN-P - February 2019...
  • Page 13 Kinetix 5700 Capacitor Module and Extension Module Apply Stud/Lug Covers Covers are included with the capacitor module and extension module and are used to protect you from the electrical hazard that is present on the DC-bus studs, lugs/wires, and flexible bus- bars that are attached to accessory modules.
  • Page 14: Additional Resources

    Resource Description Provides information on installing, configuring, starting, Kinetix 5700 Servo Drives User Manual, publication 2198-UM002 and troubleshooting your Kinetix 5700 servo drive system. Kinetix 5700 DC-bus Conditioner Modules Installation Instructions, Provides information on installing and wiring the publication 2198-IN016 Kinetix 5700 DC-bus conditioner module.
  • Page 15 Kinetix 5700 Capacitor Module and Extension Module Notes: Rockwell Automation Publication 2198-IN008D-EN-P - February 2019...
  • Page 16 Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, Encompass, Kinetix, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400...

This manual is also suitable for:

2198-capmod-dcbus-io2198-capmod-2240

Table of Contents