Bosch Rexroth EFC 3600 Operating Instructions Manual page 202

Frequency converter
Hide thumbs Also See for Rexroth EFC 3600:
Table of Contents
Bosch Rexroth AG
Appendix
Function
Name
code
Lower
b1.07
frequency
Lower
b1.08
frequency
mode
Hysteresis
b1.09
frequency width
b1.10
Direction control
Operating panel
b1.11
control direction
b1.12
~
Reserved
b1.14
Combination
frequency
b1.15
command
source
Second
frequency
b1.16
setting
source
200/235
DOK-RCON03-EFC-3600***-IT01-EN-P
Rexroth Frequency Converter EFC 3600
Setting range
0.00 ~ [b1.06]
0: Running with 0 Hz
1: Run with lower frequency
0.00 ~ [b1.07]
0: Both directions
1: Forward only
2: Reverse only
3: Inverse default direction
0: Forward; 1: Reverse
0: No combination
1: First frequency setting+
second frequency setting
2: First frequency setting -
second frequency setting
0: Given by panel potentiom‐
eter
1: Given by panel digital set‐
ting
2: Given by external analog
input voltage (AIV)
3: Given by external analog
input current (AIC)
4: Set by external UP/DOWN
terminals
5: Given via communication
6: Given by multi-speed
Min.
Factory
Attribute
unit
default
0.01 Hz 0.00 Hz
1
0
0.01
0.00
1
0
1
0
1
0
1
2
RUN/
STOP
STOP
STOP
STOP
RUN/
STOP
STOP
STOP
Table of Contents