Separation Plate / Fuser Belt Unit / Heater Lamp (Center / Side / Sub) - Toshiba e-STUDIO2330C Service Manual

Hide thumbs Also See for e-STUDIO2330C:
Table of Contents
(8)
Take off the pressure roller lamp and the
bearing from the pressure roller.
Notes:
Follow the notes below to handle the
pressure roller lamp.
When holding the lamp, grasp the glass
tube with gloved hands, but not the lead
wire and the edge.
When installing the lamp, be careful not to
hit the protrusions on it or its edge against
the pressure roller. Do not forcibly pull or
move the lamp when its edge is fixed.
Do not treat the lamp roughly, such as
letting it fall on the floor.
(9)
Remove the C-ring, and then take off the
gear and the bearing from the pressure
roller.
Note:
When installing the pressure roller, check if
the C-ring is securely engaged into the
groove of the pressure roller.
16.6.9
Separation plate / Fuser belt unit / Heater lamp (center / side /
sub)
(1)
Take off the front side cover, heat roller cover
and transport guide.
 P.16-18 "16.6.2 Front side cover"
 P.16-18 "16.6.4 Heat roller cover"
 P.16-19 "16.6.6 Transport guide"
(2)
Release the harness on the rear side out of 2
clamps and the harness guide, and then
disconnect 1 relay connector.
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
Pressure roller lamp
Bearing
Fig. 16-25
Bearing
Gear
C-ring
Fig. 16-26
Fig. 16-27
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C
16 - 23
Pressure roller
Pressure roller
Clamp
Relay connector
FUSER UNIT / PAPER EXIT SECTION
16

Hide quick links:

Table of Contents
loading

Table of Contents