Code
Item to be adjusted
396
Automatic initialization
of image quality control
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
1. While pressing [0] and [5] simultaneously, turn the power ON.
→ Adjustment Mode
2. Key in [396] and press the [START] button.
3. "WAIT" is displayed.
4. When the adjustment finishes normally, the equipment will return to
initial state of the Adjustment Mode.
When an error occurs
 P.5-15 "[F] Waste toner box replacement"
1. Replace the waste toner box with a new one and close the waste
toner cover.
2. Press and hold the [MAIN POWER] button for a few seconds to shut
down the equipment.
3. Turn the power ON.
4. Release the waste toner box full status by the warming-up
operation.
5. Check that "WAIT" is displayed.
 P.5-14 "[D] No toner in the cartridge"
1. Press and hold the [ON/OFF] button for a few seconds to shut down
the equipment in order to check the toner empty status.
2. Turn the power ON.
3. Check the toner supply operation in warming-up.
When a message prompts you to replace the toner cartridge, open
the front cover and replace the cartridge with a new one.
4. Check that "WAIT" is displayed.
Take the appropriate action described in Troubleshooting.
 P.26-1 "26. ERROR CODE AND TROUBLESHOOTING"