PLC User's Manual - Positioning Control Edition
3U
3UC
Be sure to use the class-D grounding method (grounding resistance: 100  or less).
Near-point signal (DOG)
Set the servo amplifier parameter No.21 to "020".
To ensure safety, use the forward rotation limit switch and the reverse rotation limit switch on both sides: the PLC side and
the servo amplifier side. Note that the limit switches on the PLC side should be activated slightly earlier than the limit
switches on the servo amplifier side.
Reverse rotation limit 2
Reverse rotation limit 1
(Servo amplifier side)
Servo motor
Reverse rotation
Extension blocks are used in the connection example.
Inputs and outputs built into the main unit are available in place of extension blocks.
COM0 in the FX
-40MT/ES
3G
COM3 in the FX
-40MT/ES
3G
search engine
Forward rotation limit 1
(Programmable
(Programmable
controller side)
controller side)
LSR
Forward rotation
Appendix 6. MELSERVO-C Series
Appendix 6-1 Main Unit (Transistor Output)
Forward rotation limit 2
(Servo amplifier side)