Built-in Positioning Functions
6.2

DOG Search Zero Return (DSZR Instruction)

Use this instruction to change the CLEAR signal output destination with an FX
FX
/FX
3S
6.2.1

Instruction Format

1. Instruction format
FNC 150
DSZR
ZERO RETURN
WITH DOG
SEARCH
Command
input
2. Data setting
Operand type
3. Devices
Operand
type
S
1
S
2
D
1
D
2
1 : D
2 : Specify X000 to X007 for FX
3 : Specify Y000, Y001, or Y002
*1.
*2.
*3.
Note:
• To use an FX
special adapter.
• Differential line drive type outputs will be used for the outputs of the high-speed output special adapter.
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
/FX
/FX
PLC.
3G
3GC
3U
16-bit
instruction
DSZR
9 steps
FNC150
S
S
1
2
DSZR
Specifies the near-point signal (DOG) input device number.
S
1
Specifies the zero-phase signal input number.
S
2
Specifies the pulse output number.
D
1
Specifies the rotation direction signal output destination number.
D
2
Bit device
System user
X Y M T C S D
.b KnX KnY KnM KnS T
1
  
2
3
1
4
.b is available only in FX
Specify X000 to X005 for FX
*3
Y003
from a high-speed output special adapter
Y002 is not available in FX
High-speed output special adapters can be connected only to the FX
To use Y002 and Y003 of a high-speed output special adapter, connect a second high-speed output
special adapter.
PLC of relay output type or triac output type, be sure to connect a high-speed output
3U
search engine
Instruction
Execution condition
symbol
Continuous
execution
-
type
D
D
1
2
Description
Word device
Digit designation
System user
C
D
and FX
PLCs. However, index modifiers (V and Z) are not available.
3U
3UC
/FX
/FX
/FX
PLC.
3G
3GC
3U
3UC
PLC.
3S
*1
transistor output from the main unit, or specify Y000, Y001, Y002
*2
.
PLC (14-point and 24-point type) and FX
3G
6 Mechanical Zero Return - DSZR/ZRN Instruction
6.2 DOG Search Zero Return (DSZR Instruction)
PLC Ver. 2.20 or later and
3UC
32-bit
Instruction
Execution condition
instruction
symbol
-
-
Con-
Spe-
Index
cial unit
stant
R U
\G
V Z Modify K H
/FX
PLC.
3S
3GC
PLC.
3U
A
B