3. Click on the "Individual Setting" button to display the positioning instruction settings
screen. In this screen, set the positioning table for each pulse output destination device.
Setting item
Y0
Y1
*1
Y2
*2
Y3
Rotation Direction
Signal
Head Address
No.
Positioning
Instruction
Pulse (Pls)
Frequency (Hz)
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
When the destination for pulse output on a FX
output, the setting range is 10 to 100,000 Hz.
If an FX
PLC is used, and if the pulse output destination is a high-speed output special adapter, the
3U
setting range will be 10 to 200,000 Hz.
Set the creep speed so that the relation with the other speeds is "bias speed  creep speed 
maximum speed."
The set interrupt input cannot be simultaneously used for a high-speed counter, input interruption,
pulse catch input, input for the SPD (FNC 67) instruction, or for other interrupt inputs of the DVIT
(FNC151) instruction.
Y003 is available only when two high-speed output special adapters are connected to the FX
Only available for FX
and FX
3U
Y002 is not available in FX
Click this tab to set the positioning table for Y000 (pulse output destination).
Click this tab to set the positioning table for Y001 (pulse output destination).
Click this tab to set the positioning table for Y002 (pulse output destination).
Click this tab to set the positioning table for Y003 (pulse output destination).
Set the rotation direction output number.
Initial setting:
Set the first device number to store the set data (number of pulses, frequency).
Starting from the set device, 1600 points (FX
FX
) will be occupied. Initial setting: R0
3GC
Table number
Data can be set for tables 1 to 100.
Select a positioning type from the following types:
DDVIT [Interrupt positioning instruction]
pulse instruction]", "DDRVI [Relative positioning instruction]", "DDRVA
[Absolute positioning instruction]"
Set the number of pulses to be output to perform the specified type of
positioning operation (instruction).
Set the speed (output pulse frequency) to perform the specified type of
positioning operation (instruction).
search engine
/FX
3G
3GC
PLCs.
3UC
PLC (14-point and 24-point type) and FX
3G
Description of setting
*3
Y010 for Y000 (pulse output destination)
Y011 for Y001 (pulse output destination)
Y012 for Y002 (pulse output destination)
*2
Y013 for Y003
(pulse output destination)
*4
", "DPLSV [Variable speed output
11 Batch Data Positioning Mode - TBL Instruction
11.4 Built-in Positioning Parameter Setting
/FX
or FX
PLC is a built-in transistor
3U
3UC
PLC.
3GC
/FX
) or 1200 points (FX
3U
3UC
A
B
PLC.
3U
Apx.
Setting range
-
-
-
-
FX
/FX
:
3U
3UC
Y000 to Y357
FX
/FX
:
3G
3GC
Y000 to Y177
FX
/FX
:
3U
3UC
D0 to D6400
R0 to R31168
/
3G
FX
/FX
:
3G
3GC
D0 to D6800
R0 to R22800
-
-
*5
B - 157