Appendix 1-3 Absolute Position Detection (Transistor Output); Appendix 1-3-1 Sink Input And Sink Output; Appendix 2. Melservo-J3 Series; Apx.-13 - Mitsubishi Electric FX3S Series User Manual

Hide thumbs Also See for FX3S Series:
Table of Contents
FX
/FX
/FX
3S
3G
3GC
Example Connection
*1.
*2.
*3.
*4.
*5.
*6.
*7.

Appendix 1-3 Absolute Position Detection (Transistor Output)

To assign the inputs/outputs, refer to the following section.

Appendix 1-3-1 Sink Input and Sink Output

1. FX
3S
FX
-30MT/ES
3S
Photo-coupler
*1.
Apx. - 10
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
Be sure to use the class-D grounding method (grounding resistance: 100 or less).
Near-point signal (DOG)
To ensure safety, use the forward rotation limit switch and the reverse rotation limit switch on both sides: the PLC side and
the servo amplifier side.
Note that the limit switches on the PLC side should be activated slightly earlier than the limit switches on the servo
amplifier side.
Reverse rotation limit 2
Reverse rotation limit 1
(Servo amplifier side)
Servo motor
Reverse rotation
To detect absolute positions, connect this line to the PLC.
Set the pulse output form by pulse output form setting switch.
Pulse output method setting switch
FP
RP side
PLS
DIR side
Extension blocks are used in the connection example.
Inputs and outputs built into the main unit are available in place of extension blocks.
Set the command pulse input form of the servo amplifier (PA13) MR-J4A to "021*" (negative logic, command input pulse
train filter: 500 kpps or less).
In "*", set "0" when the pulse output type of FX
train + Direction".
PLC
100 to 240 V AC
L
N
Class-D
grounding
S/S
0V
24V
X000
X014
X015
X016
X017
COM3
Y006
Y007
Y010
Y011
Be sure to use the class-D grounding method (grounding resistance: 100 or less).
search engine
Appendix 1-3 Absolute Position Detection (Transistor Output)
Forward rotation limit 1
(Programmable
(Programmable
controller side)
controller side)
LSR
Forward rotation
Pulse output method
Forward/reverse pulse train
Pulse train + direction
-2HSY-ADP is "Forward/reverse pulse train", and set "1" when it is "Pulse
3U
Refer to Section 12.1 of "B. Built-in Positioning Function"
*1
DICOM
DOCOM
24 V DC
ABS (bit0)
ABSB0
ABSB0
ABS (bit1)
ABSB123
ABSB1
Send data ready
ABST 25
ABST
Servo-ON
SON 15
ABS transfer mode
ABSM
ABS request
ABSR
Appendix 1. MELSERVO-J4 Series
Forward rotation limit 2
(Servo amplifier side)
LSF
MR-J4A
CN1
Series servo
46
amplifier
20
22
22
23
25
17
18
SD
Plate
Table of Contents
loading

This manual is also suitable for:

Fx3g seriesFx3gc seriesFx3u seriesFx3uc series

Table of Contents