Mitsubishi Electric FX3G-14M series Hardware Manual

Melsec-f fx3g series
Hide thumbs Also See for FX3G-14M series:

Quick Links

Side
B
Side
Side
A
B
JAPANESE
ENGLISH
FX
SERIES PROGRAMMABLE
3G
CONTROLLERS
HARDWARE MANUAL
Manual Number
JY997D46001
Revision
F
Date
December 2017
This manual describes the part names, dimensions, mounting,
cabling and specifications for the product. This manual is extracted
from FX
Series User's Manual - Hardware Edition. Refer to FX
3G
3G
Series User's Manual - Hardware Edition for more details. Before
use, read this manual and manuals of relevant products fully to
acquire proficiency in the handling and operating the product. Make
sure to learn all the product information, safety information, and
precautions.
And, store this manual in a safe place so that you can take it out and
read it whenever necessary. Always forward it to the end user.
Registration
Phillips is a registered trademark of Phillips Screw Company.
The company name and the product name to be described in this
manual are the registered trademarks or trademarks of each
company.
Effective December 2017
Specifications are subject to change without notice.
© 2011 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may be
impaired.
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Depending on the circumstances, procedures indicated by
may also cause severe injury.
It is important to follow all precautions for personal safety.
JY997D46001F
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Do not touch any terminal while the PLC's power is on.
Doing so may cause electric shock or malfunctions.
• Before cleaning or retightening terminals externally cut off all
phases of the power supply.
Failure to do so may cause electric shock.
• Use the battery for memory backup correctly in FX
Series
3G
User's Manual - Hardware Edition.
- Use the battery only for the specified purpose.
- Connect the battery correctly.
- Do not charge, disassemble, heat, put in fire, short-circuit,
connect reversely, weld, swallow or burn the battery, or apply
excessive forces (vibration, impact, drop, etc.) to the battery.
- Do not store or use the battery at high temperatures or
expose to direct sunlight.
- Do not expose to water, bring near fire or touch liquid
leakage or other contents directly.
- Incorrect handling of the battery may cause heat excessive
generation, bursting, ignition, liquid leakage or deformation,
and lead to injury, fire or failures and malfunctions of facilities
and other equipment.
- When replacing the battery, make sure to use our specified
product (FX
-32BL).
3U
- When a battery error occurs ("ALM" LED is lit in red), follow
the description in FX
Series User's Manual - Hardware
3G
Edition.
• Before modifying or disrupting the program in operation or
running the PLC, carefully read through this manual and the
associated manuals and ensure the safety of the operation.
An operation error may damage the machinery or cause accidents.
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Turn off the power to the PLC before attaching or detaching the
memory cassette. If the memory cassette is attached or
detached while the PLC's power is on, the data in the memory
may be destroyed, or the memory cassette may be damaged.
• Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
For repair, contact your local Mitsubishi Electric representative.
• Turn off the power to the PLC before connecting or disconnecting
any extension cable.
Failure to do so may cause equipment failures or malfunctions.
• Turn off the power to the PLC before attaching or detaching the
following devices.
Failure to do so may cause equipment failures or malfunctions.
- Peripheral devices, Display module, expansion boards, and
special adapters
- Connector conversion adapter, extension blocks, and FX
Series terminal blocks
- Battery and memory cassette
• Do not use the chemicals for cleaning.
• If there is the possibility of touching the PLC inside a control
panel in maintenance, make sure to discharge to avoid the
influence of static electricity.
DISPOSAL
PRECAUTIONS
• Please contact a certified electronic waste disposal company
for the environmentally safe recycling and disposal of your
device. When disposing of batteries, separate them from other
waste according to local regulations.
(For details of the Battery Directive in EU countries, refer to
FX
Series User's Manual - Hardware Edition.)
3G
TRANSPORTATION
AND STORAGE
PRECAUTIONS
• When transporting the FX
Series PLC incorporating the
3G
optional battery, turn on the PLC before shipment, confirm that
the battery mode is set using a parameter and the ALM LED is
OFF, and check the battery life.
If the PLC is transported with the ALM LED on or the battery
exhausted, the battery-backed data may be unstable during
transportation.
• The PLC is a precision instrument. During transportation, avoid
impacts larger than those specified in Section 2.1 by using
dedicated packaging boxes and shock-absorbing palettes.
Failure to do so may cause failures in the PLC.
After transportation, verify operation of the PLC and check for
damage of the mounting part, etc.
• When
transporting
lithium
batteries,
follow
required
transportation regulations.
(For details of the regulated products, refer to FX
Series
3G
User's Manual - Hardware Edition.)
Associated manuals
How to obtain manuals
For the necessary product manuals or documents,
consult with your local Mitsubishi Electric representative.
Associated manuals
FX
Series PLC (main unit) comes with this document (hardware
3G
manual).
For a detailed explanation of the FX
Series hardware and
3G
information on instructions for PLC programming and special
extension unit/block, refer to the relevant documents.
Manual name
Manual No.
Description
Explains FX
Series
3G
FX
Series
JY997D31301
PLC specification details
3G
User's Manual
MODEL CODE:
for I/O, wiring,
- Hardware Edition
09R521
installation, and
maintenance.
FX
/FX
/FX
/
Describes PLC
3S
3G
3GC
FX
/FX
Series
JY997D16601
programming for basic/
3U
3UC
Programming Manual
MODEL CODE:
applied instructions STL/
- Basic & Applied
09R517
SFC programming and
Instruction Edition
devices.
MELSEC-Q/L/F
Programming methods,
Structured
SH-080782
specifications, functions,
Programming
MODEL CODE:
etc. required to create
Manual
13JW06
structured programs.
(Fundamentals)
FXCPU Structured
Devices, parameters,
JY997D26001
Programming
etc.
MODEL CODE:
Manual
provided in structured
09R925
[Device & Common]
projects of GX Works2.
FXCPU Structured
Programming
JY997D34701
Sequence instructions
Manual
MODEL CODE:
provided in structured
[Basic & Applied
09R926
projects of GX Works2.
Instruction]
FXCPU Structured
Programming
JY997D34801
Application functions
Manual
MODEL CODE:
provided in structured
[Application
09R927
projects of GX Works2.
Functions]
Manual name
Manual No.
Description
FX Series
Explains N:N link,
User’s Manual
JY997D16901
parallel link, computer
- Data
MODEL CODE:
link, no protocol
Communication
09R715
communication by RS
Edition
instructions/FX
-232IF.
2N
Describes specifications
FX
/FX
/FX
/
3S
3G
3GC
for analog control and
FX
/FX
Series
JY997D16701
3U
3UC
programming methods
User's Manual
MODEL CODE:
for FX
/FX
/FX
/
3S
3G
3GC
- Analog Control
09R619
FX
/FX
Series
3U
3UC
Edition
PLC.
Explains the
FX
/FX
/FX
/
3S
3G
3GC
specifications for
FX
/FX
Series
JY997D16801
3U
3UC
positioning control of
User's Manual
MODEL CODE:
FX
/FX
/FX
/
3S
3G
3GC
- Positioning Control
09R620
FX
/FX
Series and
3U
3UC
Edition
programming procedures
Certification of UL, cUL standards
Please consult with Mitsubishi Electric for information on UL, cUL
standard practices and the corresponding types of equipment.
Compliance with EC directive(CE Marking )
This product complies with EC directive, however, this document
does not guarantee that a mechanical system including this product
will comply with EC directive.
Compliance to EMC directive and LVD directive of the entire
mechanical system should be checked by the user / manufacturer.
For more details please contact the local Mitsubishi Electric sales
site.
Caution for compliance with EC Directive
• Please use the FX
Series programmable controllers while
3G
installed in conductive shielded control panels under a general
industrial environment.
• Programmable controllers are open-type devices that must be
installed and used within conductive control panels. Please
secure the control box lid to the control box (for conduction).
Installation within a control box greatly affects the safety of the
system and aids in shielding noise from the programmable
controller.
• For the control panel, use the product having sufficient strength,
fire protectiveness and shielding property to an installation
environment.
• 24 V DC of the power supply must be supplied from the circuit
double/reinforced insulated from the main power supply (MAINS).
Caution for compliance with the LVD directive (EN61010-2-
*
201:2013)(
1)
• To an external connection port other than AC power supply
terminal and AC input/output terminal, connect the circuit
separated from a dangerous voltage by a double/reinforced
insulation.
• Between the commons having the adjacent relay output
terminals, if an external power supply is higher than 120 V AC,
the insulation is basic. Therefore, when using 120 V AC or higher
external power supply and 30 V DC/AC or lower external power
supply between the adjacent commons, do not handle 30 V DC/
AC or lower external power supply as a touchable part, (When
handling 30 V DC/AC or lower external power supply as a
touchable part, add a basic insulation.)
Table of Contents
loading

Summary of Contents for Mitsubishi Electric FX3G-14M series

  • Page 1 This manual describes the part names, dimensions, mounting, - When replacing the battery, make sure to use our specified cabling and specifications for the product. This manual is extracted Please consult with Mitsubishi Electric for information on UL, cUL product (FX -32BL).
  • Page 2: Incorporated Items

    • Do not wire two or more crimp terminals to one terminal. (If the External dimensions and weight Name wiring with two or more wires is needed, take an appropriate Installation (general specifications) Extension device connecting connector cover → For the input/output extension units/blocks, action such as adding an external terminal.) refer to FX Series User's Manual - Hardware Edition.
  • Page 3: Generic Specifications

    Generic specifications Installation location Procedures for installing to and detaching from Dielectric Insulation Terminal DIN rail strength resistance Install the PLC in an environment conforming to the generic Item Specification specifications (section 2.1), installation precautions and notes.  Main units, Input/output extension units/blocks The products can be installed on a DIN46277 rail [35 mm (1.38”) Ambient 0 to 55°C (32 to 131°F) when operating and -25 to...
  • Page 4 Procedures for installing directly (with M4 Wiring WIRING Power supply/input/output specifications screws) PRECAUTIONS This section explains the wiring of the terminal type. and examples of external wiring The product can be installed directly on the panel (with screws). For the connectors types, refer to the following manual. •...
  • Page 5: Input Specifications And External Wiring

    Power supply specifications and example of 3.2.2 Example of external wiring (AC power type) Grounding Item Specification external wiring 100 to 240V AC power is supplied to the main unit and input/output Ground the PLC as stated below. • Sink input: extension unit.
  • Page 6 3.4.3 Examples of input wiring [DC power type] 3.4.5 Input specifications (100V AC input type) Relay output specifications and example of 3.5.2 Life of relay output contact external wiring The product life of relay contacts considerably varies depending on Item Specification 1.Sink input type 2.Source input type...
  • Page 7: Transistor Output Specifications

    3.5.4 Cautions in external wiring Transistor output specifications and example of 3.6.2 External Wiring of Transistor Output Item Specification external wiring As for the details of Instructions for connecting input devices, refer to Y000, 5μs or less/10mA or more 1. External Wiring of Sink Output Type Y001 (5-24V DC) the following manual.
  • Page 8 1) The total load current of resistance loads per common The partition of the output terminals (see following figure) indicates other kind, nor does it confer any patent licenses. Mitsubishi Electric 本表格依据SJ/T 11364的规定编制。 terminal should be the following value or less.

This manual is also suitable for:

Fx3g-40m seriesFx3g-60m seriesFx3g-24m series

Table of Contents