Mitsubishi Electric FX3S Series User Manual page 138

Hide thumbs Also See for FX3S Series:
Table of Contents
FX
/FX
/FX
3S
3G
3GC
Built-in Positioning Functions
9
Check the operation of the forward rotation limit switch.
During operation in the forward rotation direction (at step 8), turn off the forward rotation limit switch
1 (X010), and confirm that the operation in the forward rotation direction is stopped.
The LED indicator lamps and the current value register (D8341, D8340) will change to the same
statuses as the stop statuses described in step 8.
In addition, the "Instruction execution abnormal end" flag (M8329) will turn on.
10
Check the operation in the reverse rotation direction.
Check the output indicator lamp (LED lamp) and the current value register to monitor the operation.
The status of the LED indicator lamp and the value indicated in the current value register depend
on the pulse output destination or rotation direction set by the positioning instruction. However, if
the pulse output destination or the rotation direction is changed for the test program, carefully read
the status of the output indicator lamp (LED lamp) and the value indicated in the current value
register to monitor the change.
1. Operation in reverse rotation direction
Turn on the reverse rotation (JOG-) switch (X013), and verify that the operation is performed in the
reverse rotation direction. For this check, set the other inputs as follows:
Input signal
1) LED indicator lamp check
Check the LED indicator lamps of the PLC or the display module to check whether the outputs are turned
on. The status of each output should be as shown in the following table:
If the transistor outputs of
the main unit are used
If the high-speed output
special adapter is used
*1.
2) Current value register (D8341, D8340) check
Monitor the current value register (D8341, D8340) of the FX
programming tool, and confirm that the value is being reduced.
B - 94
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
Status
X010
ON
X011
ON
X012
OFF
"Pulse train + direc-
"Pulse train + direc-
Reverse rotation
The output LED is kept ON in the FX
search engine
For details on the current value register, refer to Subsection 4.4.1.
Pulse output
LED lamp
method
of output
Y000
tion" method
Y004
Y0/2
tion" method
Y4/6
Forward rotation
Y0/2
pulse train (FP)
Y4/6
pulse train (RP)
PLC.
3U
For details on the current value register, refer to Subsection 4.4.1.
Status of LED lamp (output)
Turned on and off at high speed.
Kept OFF.
Turned on and off at high speed.
Kept OFF.
Kept OFF.
Turned on and off at high speed.
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
3UC
5 Operation Test
5.1 Test Procedure
*1
PLC using the
Table of Contents
loading

This manual is also suitable for:

Fx3g seriesFx3gc seriesFx3u seriesFx3uc series

Table of Contents