X31, Connection For Messages - Bosch Rexroth IndraDrive HMV01.1E-W0030 Project Planning Manual

Supply units
Hide thumbs Also See for Rexroth IndraDrive HMV01.1E-W0030:
Table of Contents
Rexroth IndraDrive

X31, Connection for Messages

Description
Graphic Representation
Connection cross section
DOK-INDRV*-HMV-*******-PR01-EN-P
The X31 interface is used as a connection for messages:
• supply unit ready for operation (Bb1)
• power supply ok (UD)
• warning signal for bleeder overload and overtemperature (WARN)
Fig. 7-24:
X31
Design
Type
LK06-1M WIN R3,5
series 0734
Fig. 7-25:
Design
Cross section
single-wire
[mm²]
0,14 - 1,5
Fig. 7-26:
Connection cross section
Electrical Installation
6
5
4
3
2
1
hmv_X31
Number of poles
6
Cross section
multiwire
[mm²]
0,14 - 1,5
7-25
Type of design
Bushing on device
Cross section
in AWG
Gauge No.
28 - 16