Hmv01.1R - Bosch Rexroth IndraDrive HMV01.1E-W0030 Project Planning Manual

Supply units
Hide thumbs Also See for Rexroth IndraDrive HMV01.1E-W0030:
Table of Contents
Rexroth IndraDrive

HMV01.1R

Mains connection with
3 x AC 380 ... 480 V (±10 %)
L1
L1
3 x AC 380 - 480 V
L2
L2
50 - 60 Hz
L3
L3
mains input
PE
KDxx
mains choke
to the central
ground connection
DOK-INDRV*-HMV-*******-PR01-EN-P
Power Supply
As the power part of the HMV01.1R power supply units consists of a
clocked 3-phase IGBT bridge, a mains choke KDxx will always be needed
for the mains connection. In addition, a so-called combining filter HFD will
be required.
HFD
combining filter
L1.1 L2.1 L3.1
twisted
Q1
U1 V1
W1
V2 W2
U2
twisted
X3
L1
L2
L3
K1
~
power
=
supply
Supply unit
HMV01.1R
Fig. 13-8:
Mains connection via mains choke and combining filter
Basically, the HFD combining filters to be provided for the mains
connection of the power supply units have two tasks:
• to suppress the current leakages from parasitic capacities of the
construction (motor cable, winding capacities) and
F2
X14
1
3
2
+24V
0V
L+
L-
to the central
ground connection
13-9
Appendix
drive
controller
HMVR_Netzanschluss.fh7
Table of Contents
loading

Table of Contents