Mechanical Mounting; Mounting Conditions; Ambient And Operating Conditions - Bosch Rexroth IndraDrive HMV01.1E-W0030 Project Planning Manual

Supply units
Hide thumbs Also See for Rexroth IndraDrive HMV01.1E-W0030:
Table of Contents
Rexroth IndraDrive
6

Mechanical Mounting

6.1

Mounting Conditions

Ambient and Operating Conditions

Designation
Ambient temperature
Ambient temperature with derating
Temperature in storage
Temperature during transportation
Mounting altitude at rating
Mounting altitude with derating*
Maximum mounting altitude*
Relative humidity
(operation)
Absolute humidity
Climatic class
Contamination level
Vibration sinus in operation according to
EN 60068-2-6
Vibration distortion (Random) in
operation according to IEC 68-2-36
DOK-INDRV*-HMV-*******-PR01-EN-P
Note:
The supply units and their additional components are designed
to be built into control cabinets.
Note:
The user must check that the ambient conditions, and in
particular the temperature of the control cabinet, are complied
with by calculating the heat levels in the control cabinet.
Information
0 to +40 °C
2% per °C to +55 °C
see chapter 5 "Transport and Storage"
see chapter 5 "Transport and Storage"
1000 m above sea level
Up to 2000 m 2.0% per 100 m from 1000 m
From 2000 m: see characteristic in Fig. 6-3
4000 m
(upper temperature limit falls to 40 °C instead of 55 °C)
5% to 95%
Cl.3K5 with reservation, as not –5 °C
3
1 to 29 g/m
Cl.3K5
Contamination level 2 in accordance with EN50178
Amplitude and frequency:
Acceleration and frequency:
Tolerance:
Frequency:
Spectral acceleration density amplitude:
Tolerance:
Virtual value (r.m.s.) of the total acceleration:
*
For mounting altitudes of more than 2000 m, an overvoltage limiter
for transient overvoltage 1.2/50 µs must be installed in the
installation or building in order to limit the voltage to 1.0 kV between
the outer conductors and to 2.5 kV between conductor-ground.
Fig. 6-1:
Ambient and operating conditions
6-1
Mechanical Mounting
0,15 mm (peak-peak)
at 10 ... 57 Hz
1 g at 57 ... 150 Hz
±15 %
20 ... 150 Hz
2
0,005 g
/Hz
± 3 dB
1,0 g
Table of Contents
loading

Table of Contents