Quick Links

H-Series Condensing Unit
User Manual
Table of Contents
loading

Summary of Contents for Emerson COPELAND H Series

  • Page 1 H-Series Condensing Unit User Manual...
  • Page 2: Table Of Contents

    Table of Contents Content Page Introduction Safety Information Nomenclature CDU Models & Data Features & Benefits Physical Layout Dimensional Drawings Electrical Connections Installation & Startup Operational Checklist...
  • Page 3: Introduction

    Introduction Thank you for purchasing the Emerson™ H-Series Condensing Unit. We hope that this product meets your intended refrigeration requirement. Please read through this operation manual to familiarize yourself with the installation, com- missioning, and operation of this product. Please do read the following informa- tion in this page before proceeding with the rest of the manual.
  • Page 4: Safety Information

    1. Safety Information 1.1 Installation and commissioning work on CDU shall be carried out only by qualified, refrigeration personnel who have been trained and instructed. 1.2 H-Series condensing unit is manufactured according to the latest safety standards. Emphasis has been placed on the user’s safety. For relevant stan- dards please refer to the manufacturer’s declaration, available on request.
  • Page 5 1.5 General Instructions 1.6 Safety Refrigerants/Lubricant Please use correct refrigerant as designed to work in safe operating envelope. Compressor is supplied with an initial oil charge. The standard oil charge for use with HFC refrigerant is polyol ester (POE) lubricant Emkarate RL 32 3MAF.
  • Page 6: Nomenclature

    2. Nomenclature H M X A - 0 1 5 - T F M - 5 1 1 Revision no. Nominal HP Family series Bill of material Platform 015: 1.5HP H - series Scope of supply Application range Unit voltage code Code Application Refrigerant...
  • Page 7: Features & Benefits

    Specially designed condenser. Compressor is provided with Emerson EVI CoreSense™ kits to control superheat of vapor injection and to maintain safe discharge temperature in dual temperature application. Fully featured options such as filter drier, sight glass, oil separator and suction accumulator available as Reliability standard scope of supply in dual temperature models.
  • Page 8: Physical Layout

    Condenser Internally grooved copper tubes with hydrophilic coated aluminum fins. Fan Motors Thermally protected, single-phase fans. Option to have fan speed controller. 5. Physical Layout of the Dual Temperature Unit CoreSense / Condenser Block Injection Management Fan Motor Oil Separator Suction Accumulator Liquid Receiver...
  • Page 9: Dimensional Drawings

    6. Dimensional drawings 1029 2 HOLESØ15MM DIA Power Supply Hole Suction Service Valve Liquid Service Valve 2-R7.5MM GROOVE Single Fan Unit 1.5 - 4 HP 1029 2 HOLESØ15MM DIA 1242 Power Supply Hole Suction Service Valve 2-R7.5MM GROOVE Liquid Service Valve Dual Fan Unit 5 - 7.5 HP 7.
  • Page 10: Electrical Connections

    8. Electrical connections ELECTRONIC EXPANSION VALVE DLT SENSOR VAPOR IN SENSOR VAPOR OUT SENSOR...
  • Page 11 BU / BK YE / CGY RD / LGY...
  • Page 12 9. EVI CoreSense™ control kits and LED Indications EVI CoreSense control kits The EVI CoreSense control kit of Dual Temperature H-Series unit is intended to control vapor injection, maintain a safe discharge temperature, and provide intelligent diagnosis and protection. The kit includes a printed circuit board (PCB), an electronic expansion valve (EXV), and three sensors, as well as containing a transformer and an EXV filter.
  • Page 13 DIP Switch Setting Bit 1 Bit 2 DLT Control Point Default Bit 1 Reset Mode Default 95 deg C Lockout A�er 5 trips in 1 hr 100 deg C Auto Reset 105 deg C Bit2 Vapour Injection Superheat 110 deg C 10 deg K C DLT 5 deg K...
  • Page 14: Installation & Startup

    (specify the extent and type of damage found). Unit should be inspected carefully for concealed damage. Notify Emerson sales/application personnel of the damage immediately. Request an immediate joint inspection and do not repair the unit until inspected by Emerson’s representative.
  • Page 15 c. Refrigeration Piping Installation All interconnecting pipes should be of refrigeration grade, clean, dehydrated and must remain capped at both ends until installation. Even during installation, if the system is left for any reasonable period (say two hours), pipes should be re- capped to prevent moisture and contaminants from entering the system.
  • Page 16 e. Electrical All electrical work must be done in accordance with the National Electrical Code and existing local codes. Power supply must be the same as specified on the unit’s name plate. Voltage fluctuations in excess of 10 percent must be corrected. Before starting the unit, ensure that all protective devices are in place and that all wiring is secure.
  • Page 17 g. Start-up & Operation Initial pressure test (by vacuum and nitrogen) - Step-by-step: Use a 4-port gauge manifold with 3/8” hose and connections to the vacuum pump. The vacuum gauge does not have to be connected for this part of the process.
  • Page 18 Ensure that all service valves are open during the leak test process. It is important to recheck all joints within the unit as well as the external joints. The unit is shipped with a holding charge of dry nitrogen and should be leak free.
  • Page 19 Step-by-step: Ensure that there is no power supply to the H-Series unit. The Liquid Line solenoid needs to be kept open for the charging process and this may require a temporary power feed to it. Connect the refrigerant cylinder to main service hose and purge line at the manifold end.
  • Page 20: Operational Checklist

    System Start-Up and Operational Check Sheet Client Details Facility/Customer Name : Address : Contact Details : Installer : Installation Date : Condensing Unit Info CDU Model : Serial Number : CDU Location : Indoor Unit Make/Model : System Details System Operation Room/Case ID : COMP Voltage : Pipe Length (approx.) :...
  • Page 21 Technical data given was correct at the time of printing. Products, specifications and data in this literature are subject to change without prior notice. Updates will be done periodically. Should you need clarification of a specific data, value or information, kindly contact Emerson representative. Contact list United Arab Emirates...

Table of Contents