Installation And Removal Of Modules - Mitsubishi Electric SD Series Installation Description

Industrial robots
Table of Contents
Installation
3.5.1

Installation and removal of modules

This section shows you how to assemble modules onto the rack such as, e.g. power supply unit, a PLC
or a robot CPU.
ATTENTION:
E
● The mains voltage must always be switched off before installing a module.
● If the module is not placed correctly over the catch on the rack then the PINs on the module
plug might become bent.
Installation
● Switch off the mains voltage!
● Place the module with the lower catch into the guide on the rack.
● Then press the module onto the rack until it is lying fully onto the rack.
● Additionally secure the module with a screw (M3 x 12) if vibrations are to be expected. This screw
is not supplied with the module. The robot CPU must always be secured with a fixing screw.
Fig. 3-16: Installation of the module
SD-/SQ series
Rack
Slot
Guide
Catch
Installation of robot CPU Q172DRCPU
Rack
Module
Catch
Lock
QH0007E
3 - 19