Example System With An Ma Remote Controller; Single Refrigerant System (Automatic Indoor/Outdoor Address Startup) - Mitsubishi Electric PURY-HP72 Service Handbook

R410a
Hide thumbs Also See for PURY-HP72:
Table of Contents

[2-7 Example System with an MA Remote Controller ]

2-7

Example System with an MA Remote Controller

2-7-1

Single Refrigerant System (Automatic Indoor/Outdoor Address Startup)

(1) Sample control wiring
L1
Leave the male
Leave the male
connector on
connector on
CN41 as it is.
CN41 as it is.
SW5-1 OFF
SW5-1 OFF
OS
00
TB3
TB7
TB3
M1 M2
M1 M2
S
M1 M2
*1. When BS is connected to the system,
automatic address setup is not available.
(2) Cautions
1) ME remote controller and MA remote controller cannot both
be connected to the same group of indoor units.
2) No more than 2 MA remote controllers can be connected to
a group of indoor units. It is not possible to connect a pair of
PAR-30MAAU.
3) When the number of the connected indoor units is as shown
in the table below, one or more transmission boosters (sold
separately) are required.
To connect two transmission boosters, connect them in par-
allel. (Observe the maximum number of connectable indoor
units that are listed in the specifications for each outdoor
unit.)
When the P72 and P96 models
are not included in the connect-
ed indoor units
When the P72 and P96 models
are included in the connected
indoor units
The table above shows the number of transmission boost-
ers that is required by the system with three BC controllers.
For each BC controller that is subtracted from the above-
mentioned system, two additional indoor units can be con-
nected.
HWE13080
L2
L3
Group
OC
BC
00
00
TB7
TB02
M1 M2
S
M1 M2 S
*1
M1M2
S
TB02
00
Group
BS
A1 B2
MA
Number of transmission
booster (sold separately) re-
quired
1 unit
2 units
27 - 50 units
-
21 - 39 units
40 - 50 units
L4
Group
IC
IC
00
00
TB5
TB15
TB5
TB15
M1 M2
S
1 2
M1 M2
S
1 2
A1 B2
A1 B2
A1 B2
MA
RC
L12
Group
IC
IC
00
00
TB5
TB15
TB5
TB15
M1 M2
S
1 2
M1 M2
S
1 2
A1 B2
A1 B2
A1 B2
MA
MA
MA
4) Automatic address setup is not available if start-stop input
(CN32, CN51, CN41) is used for a group operation of indoor
units or when multiple indoor units with different functions
are grouped in the same group. Refer to the following
page(s). [2-7-2 Single Refrigerant System with Two or More
LOSSNAY Units](page 34)
5) For information about connecting two or more LOSSNAY
units to a system, refer to the following page(s). [2-7-2 Sin-
gle Refrigerant System with Two or More LOSSNAY
Units](page 34)
(3) Maximum allowable length
1) Indoor/outdoor transmission line
Maximum distance (1.25mm
L1 +L2+L3+L4+L5 200m[656ft]
L1 +L2+L3+L11+L12+L13 200m[656ft]
2) Transmission line for centralized control
No connection is required.
3) MA remote controller wiring
Maximum overall line length
2
(0.3 to 1.25mm
m1 200m [656ft]
m2+m3 200m [656ft]
m4+m5 200m [656ft]
*When connected to the terminal block on the Simple re-
mote controller, use cables that meet the following cable
size specifications: 0.75 - 1.25 mm
*When connecting PAR-30MAAU, use a 0.3 mm
sheathed cable.
- 32 -
Interlock operation with
the ventilation unit
L5
LC
00
TB5
M1 M2
S
MA
L13
IC
00
TB5
TB15
M1 M2
S
1 2
m3
2
[AWG16] or larger)
[AWG22 to 16])
2
[AWG18-14].
2
GB
Table of Contents
loading

Table of Contents