Installing A Power-Fan Canister; After Replacing A Power-Fan Canister; Seven-Segment Display Codes - Bosch DSX-N1D8X4-12AT Installaton Manual

Hide thumbs Also See for DSX-N1D8X4-12AT:
Table of Contents
DSA E-Series (E2800 12-bay)
8.2.3

Installing a power-fan canister

To install a power-fan canister:
1.
2.
3.
4.
5.
8.2.4

After replacing a power-fan canister

After replacing a power-fan canister, you must confirm that the new power-fan canister is
working correctly. Then, you can gather support data and resume operations.
To confirm that the power-fan canister is working correctly:
1.
2.
3.
4.
5.
8.3

Seven-segment display codes

The following chapters explain the codes that are displayed on the seven-segment-display.
Bosch Security Systems B.V.
Make sure that the on/off switch of the new power supply is in the Off position.
Using both hands, support and align the edges of the power supply with the opening in
the system chassis, and then gently push the power supply into the chassis using the cam
handle.
The power supplies are keyed and can only be installed one way.
Note: Do not use excessive force when sliding the power supply into the system; you can
damage the connector.
Close the cam handle so that the latch clicks into the locked position and the power
supply is fully seated.
Reconnect the power supply cabling as follows:
Reconnect the power cord to the power supply and the power source.
Secure the power cord to the power supply using the power cord retainer.
Turn on the power to the new power-fan canister.
Check the green Power LED and the amber Attention LED on the new power-fan canister.
The green LED should be on and the amber LED should be off (see LEDs on the power-
fan canister, page 17 ).
From the Recovery Guru in SANtricity System Manager, select Recheck to ensure the
problem has been resolved.
If a failed power-fan canister is still being reported, repeat the steps in the following
sections:
Removing a power-fan canister, page 40
Installing a power-fan canister, page 41
If the problem continues to persist, contact technical support.
Remove the antistatic protection.
Collect support data for your storage system (see Collecting support data for the storage
system, page 46 ).
Note: Collecting support data before and after replacing a component ensures you can
send a full set of logs to technical support in case the replacement does not resolve the
problem.
Seven-segment display sequence codes, page 42
Seven-segment display codes when controller turns on, page 43
Seven-segment display use cases, page 43
Seven-segment display lock-down codes, page 44
Installaton manual
Maintenance | en
41