8.1.2 Removing a drive 8.1.3 Installing a drive 8.1.4 After replacing a drive Replacing a power canister 8.2.1 Preparing to remove a power canister 8.2.2 Removing a power canister Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
Page 4
Seven-segment display sequence codes 8.4.2 Seven-segment display codes when controller turns on 8.4.3 Seven-segment display use cases 8.4.4 Seven-segment display lock-down codes Collecting support data for the storage system 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
Permanently connected devices must have an external, readily operable mains plug or all‑pole mains switch in accordance with installation rules. – Pluggable devices must have an easily accessible socket-outlet installed near the equipment. Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
Page 6
SELV circuits. – If safe operation of the unit cannot be ensured, remove it from service and secure it to prevent unauthorized operation. In such cases, have the unit checked by Bosch Security Systems. –...
Do not remove more than one canister from the enclosure while power to the enclosure is turned on. – Bosch products may contain Class 1 laser devices, Class 1M laser devices, or both. – Keep away from moving fan blades.
Notice! This is a class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
Page 9
Safety | en Notice! Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of losing information, we recommend multiple, redundant recording systems, and a procedure to back up all analog and digital information.
Bosch Product Registration page. Registering your device using an existing NetApp NOW account Sign in to your NetApp NOW account and register your device here. Creating a new account using the Bosch Product Registration page Please register your product: https://www.boschsecurity.com/product-registration/...
Each controller unit and expansion unit has LEDs located on the operator display panel. The operator display panel is visible through the front bezel of a controller unit and through the left end cap of an expansion unit. 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
The back of the controller unit includes LEDs that indicate the status of the controller. For example, the controller is active, the controller needs attention, or when there is Ethernet activity. Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
Page 14
The controller is active. Ethernet activity (right) Green The link between the management port and the device to which it is connected (such as an Ethernet switch) is up. 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
The I/O module (IOM) includes the SAS ports for connecting the expansion units to the controller units or to other expansion units. SAS port attention LED SAS port link LED Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
Description Activity Green The drive has power. Blinking green The drive has power, and I/O is in process. Attention Amber An error occurred with the functioning of the drive. 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
Drive I/O activity is taking place. Within a drive drawer, there are 12 drive slots numbered 0 through 11. Each drive uses an amber Attention LED that comes on if the drive requires operator attention Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
The fan canister has an Attention LED that is identified by a sideways exclamation point in the middle of the canister. Each 60-bay controller unit and 60-expansion unit has two fan canisters, one on either side of the enclosure. 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
Page 19
DSA E-Series (E2800 60-bay) System overview | en Attention LED Solid amber: The fan is faulty. Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
You can install the unit in either a square-hole or round-hole rack. – If you are installing the unit in a cabinet not provided by Bosch: – Ensure that the rack is adequate for the weight and size of the unit to be installed.
You can install the unit in either a square-hole or round-hole rack. – If you are installing the unit in a cabinet not provided by Bosch: – Ensure that the rack is adequate for the weight and size of the unit to be installed.
Page 22
Replace the system bezel when you are done. Note: Do not place additional equipment on the rails after you finish installing the unit. The rails are not designed to bear additional weight. 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
Note: Whenever possible, install the units from the bottom of the rack up, so that you can use the units underneath as a guide for installing the next set of rails. Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
Page 24
Hook in the left rail in the adapter brackets and tighten all screws completely to hold the rail firmly in place. – Repeat this step for the right rail. M4x15 Place the back of the unit (the end with the connectors) on the rails. 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
Page 25
M4x15 If applicable, replace the end caps or the system bezel. Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
Lock in the desired number, and exit the programming mode by pressing and holding the ODP button until the second number stops blinking. Note: It can take up to three seconds for the second number to stop blinking. Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
Connecting the controller unit to the network In case of a Bosch Video Recording Solution a host is an IP camera. To connect the controller unit to the Ethernet one or two of two available iSCSI host ports must be connected to the Ethernet.
Connect Ethernet cables between port 1 of controller A and port 1 of controller B to an external Ethernet switch or hub. Connect the management host to the Ethernet switch or hub. Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
To connect the controller unit and the expansion units to the power supply: Confirm that the two power switches on the controller unit are off. Note: If you have expansion units, confirm that their power switches are off. 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
If any of the amber LEDs are on, there might be a problem with a component. Confirm you completed the installation steps correctly. If you are unable to resolve the problem, contact your local Bosch Technical Support team. Supported connections We recommend using the following connection methods: Bosch Security Systems B.V.
Page 32
Channel 6 / Controller A is the fallback of Channel 6 /. Controller B – Alternatively: iSCSI, optical Note: – Channel 3 / Controller B is the fallback of Channel 3 / Controller A and Channel 4 / Controller A is the fallback of Channel 4 /. Controller B 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
If any of the amber LEDs are on, there might be a problem with a component. Confirm you completed the installation steps correctly. If you are unable to resolve the problem, contact your local Bosch Technical Support team. Connect all cables if required.
Task format and a warning message box is displayed that informs you that formatting a disk will erase all data. 17. Click Yes to confirm. The status of the LUNs changes to Ready. The LUNs are formatted. 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
Attention LED is on. You can hot-swap a failed drive while the unit is receiving I/O operations. Before you begin – You have a replacement drive that is supported by Bosch for the controller unit or expansion unit. – You have an ESD wristband, or you have taken other antistatic precautions.
The drive drawer's amber Attention LED blinks so you can open the correct drive drawer to identify which drive to replace. Note: The drive drawer Attention LEDs are on the left side in front of each drive, with 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
If you have not already done so, carefully pull on the extended drive drawer levers to pull out the drive drawer to its full extension without removing it from the enclosure. Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
Install the replacement drive as soon as possible after removing the failed drive. Otherwise, there is a risk that the equipment might overheat. To install a drive: Raise the cam handle on the new drive to vertical. 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
The drive might not be installed correctly. Remove the drive, wait 30 seconds, and then reinstall it. The drive drawer’s Attention LED is on. The new drive might be defective. Replace it with another new drive. Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
When the drive reconstruction completes, the volume group is in an optimal state. As required, reinstall the bezel on the front of the unit. Return the failed part to Bosch, as described in the RMA instructions shipped with the kit.
You can also find information about the failed power canister in the Details area of the Recovery Guru, or you can review the information displayed for the shelf, or you can review the Event Log under Support and filter by Component Type. Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
If a failed power canister is still being reported, repeat the steps in Removing a power canister, page 42 and Installing a power canister, page 42 . If the problem continues to persist, contact technical support. 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
If the second fan canister in the unit does not have Optimal status or if the Recovery Guru indicates that it is not OK to remove the fan canister, contact your technical support. To replace a fan canister observe the instructions in the following chapters: Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
From the back of the storage array, look at the Attention LEDs to locate the fan canister you need to remove. You must replace the fan canister that has its Attention LED on. 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
The LED goes off after this process is complete. From the Recovery Guru in SANtricity System Manager, select Recheck to ensure the problem has been resolved. Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
SATA drive initialization 0x92 - 0x96 PCI bus initialization 8.4.3 Seven-segment display use cases The following table shows seven-segment display use cases and the sequence that is displayed in each case: Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
Page 48
OE L2 -- CF dx blank- errors The controller is suspended as a result of persistent cache backup configuration errors The write-protect switch is set during cache OE LC blank- restore 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
A HIC configuration error has been detected. A persistent cache backup configuration error has been detected. A mixed cache memory DIMMs condition has been detected. Uncertified cache memory DIMM sizes have been detected. Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...
The file is saved in the Downloads folder for your browser with the name supportdata.7z Collecting support data using Script editor in the EMW Open the Enterprise Management Window (EMW) in SANtricity Storage Manager on your local host. 2020-05 | V2 | DOC Installation manual Bosch Security Systems B.V.
Page 51
In this command, filename is the file path and the file name to which you want to save the support data. Enclose the file path and the file name in double quotation marks (" "). For example: file="C:\Program Files\CLI\logs\support-data.7z" Select Tools > Verify and Execute Bosch Security Systems B.V. Installation manual 2020-05 | V2 | DOC...