Quick Start Guide September 2020 NOTICE This guide provides basic guidelines for the Emerson Gateway. It does not provide instructions for diagnostics, maintenance, service, or troubleshooting. Refer to the Emerson Gateway Reference Manual for more information and instructions. This guide and the manual are available electronically on www.emerson.com.
15 to 25 ft. (4,6 to 7,6 m) above ground or 6 ft. (2 m) above obstructions or major infrastructure. Gateway redundancy If the wireless Gateway was ordered with redundancy (Gateway Redundancy code RD), refer to Appendix D in the Emerson Wireless Gateway Reference Manual for additional installation instructions.
Windows 7 Enterprise, Service Pack 1 Applications ® • Internet Explorer 6.0 or higher ® • Mozilla Firefox 1.5 or higher • .Net Framework 2.0 (for OPC proxy only) Hard disk space • AMS Wireless Configurator: 1.5 GB • Gateway Setup CD: 250 MB Emerson.com/Rosemount...
September 2020 Quick Start Guide Initial connection and configuration ™ DeltaV ready If the Gateway was ordered DeltaV Ready (Data Protocols Code 5), then skip Physical installation, and connect the Gateway to a DeltaV 10.3 or newer control network. Initial connection and configuration To configure the Gateway, a local connection between a PC/laptop and the Gateway needs to be established.
Page 6
PoE jumper matrix. Note The Gateway enclosure case should always grounded in accordance with national and local electrical codes. The most effective grounding method is a direct connection to earth ground with minimal impedance. Emerson.com/Rosemount...
Page 7
September 2020 Quick Start Guide Figure 3-3: Emerson 1420 PoE Jumpering Matrix (Located on 1420 Board) Black fill below indicates jumper. PoE PD on port 1 (Default jumpering for production. Used for no PoE also) PoE PD on port 2...
Page 8
25.5 W of power. The 2009 standard prohibits a powered device from using all four pairs for power. For more information on PoE and frequently asked questions, reference the Emerson Wireless Gateway white paper. Establishing a connection...
Page 9
September 2020 Quick Start Guide b) Right click to select Properties. c) Select Internet Protocol (TCP/IP), then select the Properties button. Note If the PC/laptop is from another network, record the current IP address and other settings so the PC/laptop can be returned to the original network after the Gateway has been configured.
Page 10
Subnet mask Default 255.255.255.0 DeltaV 255.254.0.0 3. Disable proxies. a) Open a standard web browser (Internet Explorer, Mozilla Firefox, or other). b) Navigate to Tools → Internet Options → Connections → LAN Settings. c) Uncheck the box under Proxy Server. Emerson.com/Rosemount...
Page 11
September 2020 Quick Start Guide Configure the Gateway To complete initial configuration for the Gateway: Procedure 1. Access the default web page for the Gateway at https:// 192.168.1.10. a) In the User name field, enter admin. b) In the Password field, enter default. Figure 3-5: Gateway Log In Screen 2.
Page 12
Quick Start Guide September 2020 Emerson.com/Rosemount...
September 2020 Quick Start Guide Physical installation Pipe mount Tools needed: • 2-in. (51 mm) mounting pipe or mast • Two 5/16-in. (7,9 mm) u-bolts supplied with Gateway • 1/2-in. socket-head wrench For installing the Gateway with a pipe mount: Procedure 1.
Page 14
If the supplied remote mount antenna kit is not installed per these instructions, Emerson is not responsible for wireless performance or non- compliance with spectrum regulations. The remote mount antenna kit includes coaxial sealant for the cable connections for the lightning arrestor and antenna.
Page 15
September 2020 Quick Start Guide Figure 4-1: Installation of WL2/WN2 Option Control building Lightning arrestor Remote antenna Gateway Cable Ground Drip loop Earth Installation of WL3/WL4 option (indoor to outdoor applications) Procedure 1. Mount the antenna on a 1.5 to 2-in. pipe mast using the supplied mounting equipment.
Page 16
7. Ensure the mounting mast, lightning arrestor, and Gateway are grounded according to local/national electrical codes. 8. Place any spare lengths of coaxial cable in 12-in. (0,3 m) coils. Figure 4-2: Installation of WL3/WL4 Option Control building Lightning arrestor Remote antenna Gateway Cable Ground Drip loop Earth Emerson.com/Rosemount...
Page 17
September 2020 Quick Start Guide Note Weather proofing is required! The remote mount antenna kit includes coaxial sealant for the cable connections for the lightning arrestor, antenna, and Gateway. The coaxial sealant must be applied to guarantee performance of the wireless field network. See Figure for details on applying weather proofing.
Page 18
30 ft. (9,1m) cable 10 ft. (3,0 m) cable 40 ft. (12,2 m) cable Lightning arrestor 25 ft. (7,6m) cable Interchangeable cables Note The coaxial cables on the remote antenna options WL3 and WL4 are interchangeable for installation convenience. Emerson.com/Rosemount...
September 2020 Quick Start Guide Connect to the host system Procedure 1. Wire the Gateway’s Ethernet 1 (Primary) or Serial Output connection to the Host System Network or Serial I/O. 2. For serial connections, connect A to A, B to B, making sure all terminations are clean and secured to avoid wiring connection problems.
Page 20
Quick Start Guide September 2020 Best practice ® In accordance with Emerson WirelessHART security guidelines, the Gateway should be connected to the Host System via a LAN (Local Area Network) and not a WAN (Wide Area Network). Twisted shielded pair cable is generally used to wire the serial connection, and it is standard practice to ground the shield on the serial host side leaving the shield floating on the Gateway side.
D:\SETUP.EXE (where D is the CD/DVD drive on the PC) and select OK. For more information about the Security Setup Utility and AMS Wireless Configurator, see the Emerson Wireless Gateway Reference Manual (document number 00809-0200-4420). Quick Start Guide...
ID and join key information. Once the field devices are powered, they will appear on the wireless network and communications can be verified under the Explore tab using the web interface. The time needed for the network to form depends on the number of devices. Emerson.com/Rosemount...
September 2020 Quick Start Guide Product specifications Input power 10.5–30 VDC (must be a Class 2 power supply) Current draw Operating current draw is based on 3.6 W average power consumption. Momentary startup current draw up to twice operating current draw. Maximum permissible current: 1A Operating Region...
Page 24
Protocol: Modbus RTU Wiring: Single twisted shielded pair, 18 AWG Wiring distance: up to 4,000 ft. (1,524 m) Ethernet 10/1000base- TXEthernet communication port ™ ™ Protocols: EtherNet/IP Modbus TCP, OPC, HART-IP , HTTPS (for Web Interface) Wiring: Cat5Eshielded cable Emerson.com/Rosemount...
Page 25
September 2020 Quick Start Guide Wiring distance: 328 ft. (100 m) Modbus Supports Modbus RTU and Modbus TCP with 32-bit floating point values, integers, and scaled integers. Modbus Registers are user-specified. OPC server supports OPC DA v2, v3 Ethernet/IP Supports Ethernet/IP protocol with 32-bit floating point values and integers. Ethernet/IP assembly input-output instances are user configurable.
RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage.
Page 27
September 2020 Quick Start Guide Standards FM Class 3600 - 2011, FM Class 3611 - 2004, FM Class 3616 - 2011, UL 50 - 11 Ed, ANSI/ISA 61010-1 - 2012 Markings NI CL 1, DIV 2, GP A, B, C, D T4; Suitable for use in CL II, III, DIV 2, GP F, G T4;...
Page 28
1. The surface resistivity of the antenna is greater than 1GΩ. To avoid electrostatic charge build-up, it must not be rubbed with a dry cloth or cleaned with solvents. 9.10 Brazil N2 INMETRO Type n Certificate UL-BR 15.0350X Standards ABNT NBR IEC 60079-0:2008 + Errata 1:2011, IEC 60079-15:2012; Emerson.com/Rosemount...
Page 31
September 2020 Quick Start Guide Figure 9-1: Emerson Wireless Gateway 1420 Declaration of Conformity Quick Start Guide...
Page 32
Quick Start Guide September 2020 Emerson.com/Rosemount...
Page 33
September 2020 Quick Start Guide Quick Start Guide...