Determining The Error Class; Customer Self Service (Css) Indicator; Global Error Indicator - Fujitsu PRIMERGY RX2540 M2 Upgrade And Maintenance Manual

Table of Contents
Basic hardware procedures
4.1.2

Determining the error class

The Local Service Concept (LSC) allows you to identify defective server
components. Failure events are assigned to one of two error classes:
– Global Error events that need to be resolved by maintenance personnel
– Customer Self Service (CSS) error events that may be resolved by
operating personnel
Global Error and CSS LEDs indicate, if the defective component is a customer
replaceable unit or if maintenance personnel needs to be dispatched to replace
the part.
I
The indicators also light up in standby mode and after a server restart
due to a power failure.
4.1.2.1

Customer Self Service (CSS) indicator

Ê Check the CSS indicator on the front panel or connector panel of the server:
Ê For further diagnostics, proceed as follows:
– Hardware errors:
Check the System Event Log (SEL) as described in section
SEL" on page
– Software / agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I
For further information, please refer to the "ServerView System
Monitor" user guide.
4.1.2.2

Global Error indicator

Ê Check the Global Error indicator on the front or connector panel of the
server:
Ê For further diagnostics, proceed as follows:
– Hardware errors:
Check the System Event Log (SEL) as described in section
SEL" on page
62
117.
117.