Fujitsu PRIMERGY RX2540 M2 Upgrade And Maintenance Manual page 594

Table of Contents
Appendix
Pos.
Label
1
ID
2
[CSS]
I
Note on CSS and Global Error indicators on the I/O panel
If CSS and Global Error indicators are located in the same place on your
server's I/O panel, please also check the indicators on the front panel to
determine if a CSS or Global Error event has been detected.
594
Indicator
Status
off
orange on
Global Error
indicator,
see also
"iRMC-
related
status
orange
signals" on
flashing
page 595
ID indicator,
blue on
see also
"iRMC-
related
status
signals" on
blue
page 595
flashing
off
CSS
orange on
indicator
orange
flashing
Upgrade and Maintenance Manual
Description
No critical event detected (non CSS
component).
Prefailure event detected (non CSS
component).
Non CSS component failure
detected.
Possible causes:
– System is out of the specified
temperature range
– Defective sensor
– CPU error
– Error detected by server
management software
The server has been highlighted
using ServerView Operations
Manager, iRMC web frontend or the
ID button on the front panel for easy
identification
The server has been highlighted for
easy identification using the iRMC
(AVR) with disabled local VGA
output.
No critical event detected (CSS
component).
Prefailure event detected (CSS
component).
For HDDs see also
prefailure detection" on page 595
CSS component failure detected.
"HDD
RX2540 M2

Hide quick links:

Table of Contents
loading

Table of Contents