2
Fujitsu PRIMERGY RX2540 M6 manuals available for free PDF download: Upgrade And Maintenance Manual, Operating Manual
Fujitsu PRIMERGY RX2540 M6 Upgrade And Maintenance Manual (680 pages)
Brand:
Fujitsu
| Category:
Server
| Size: 17.82 MB
Table of Contents
Table of Contents
9
Introduction
21
Concept and Target Groups of this Manual
21
Notational Conventions
21
Before You Start
23
Basic Information
23
Proceeding
23
Advanced Thermal Design (ATD)
23
Configuration Thermal Design (CTD)
24
Installing Optional Components
24
Assignment of Unit Categories
25
Classification of Procedures
25
Replacing a Defective Component
25
Customer Replaceable Units (CRU)
26
Upgrade and Repair Units (URU)
27
Field Replaceable Units (FRU)
28
Average Task Duration
29
Tools You Need at Hand
30
Documentation Overview
30
Downloading Manuals
30
List of Documents
31
Important Information
35
Introduction
35
Safety Instructions
35
Basic Safety Instructions
35
Before Starting up
36
Installation and Operation
36
Batteries
39
Working with Optical Disk Drives (Odds) and Media
39
Laser Information
41
Modules with Electrostatic-Sensitive Devices (ESD Modules)
41
Transporting the Server
43
Installing the Server in the Rack
44
Other Important Information
44
CE Conformity
45
FCC Class a Compliance Statement
45
Environmental Protection
46
Locating the Defective Server
49
Using Diagnostic Information
49
Proceeding
49
Basic Hardware Procedures
49
Determining the Error Class
50
Locating the Defective Component
50
Removing the Front Cover with Lock
52
Shutting down the Server
52
Disconnecting the Power Cord
53
Disconnecting the Power Cord (AC PSU)
53
Disconnecting the Power Cord (DC PSU)
54
Getting Access to the Component
56
Safety Notes
56
Extending the Server out of the Rack
56
Removing the Server from the Rack
57
Removing the Top Covers
59
Reassembling
60
Safety Notes
60
Installing the Top Covers
61
Installing the Server in the Rack
62
Sliding the Server into the Rack
64
Connecting the Power Cord
65
Connecting the Power Cord (AC PSU)
65
Connecting the Power Cord (DC PSU)
66
Switching on the Server
69
Installing the Front Cover with Lock
69
Removing a Riser Module
70
Handling Riser Modules
70
Installing a Riser Module
72
Handling the Fan Cage
74
Removing the Fan Cage
74
Installing the Fan Cage
76
Handling the Air Duct
78
Removing the Air Duct
78
Installing the Air Duct
79
Handling the Cross Bar
80
Removing the Cross Bar
80
Installing the Cross Bar
81
Handling the Rear Air Grids
82
Removing a Rear Air Grid
82
Installing a Rear Air Grid
84
Basic Software Procedures
87
Validation
87
Starting the Maintenance Task
87
Suspending Bitlocker Functionality
87
Disabling the Boot Watchdog
88
Removing Backup and Optical Disk Media
90
Verifying and Configuring the Backup Software Solution
90
Switching on the ID Indicator
90
Completing the Maintenance Task
91
Updating or Recovering the BIOS and Irmc S5
91
Verifying System Information Backup or Restore
94
Updating Expansion Card Firmware
95
Reconfiguring the Backup Software Solution
96
Resetting the Boot Retry Counter
97
Enabling the Boot Watchdog
99
Enabling Replaced Components in the BIOS
100
Verifying the System Time Settings
100
Viewing and Clearing the System Event Log (SEL)
101
Updating the NIC Configuration File in a Linux and Vmware Environment
104
Resuming Bitlocker Functionality
105
Performing a RAID Array Rebuild
106
Looking for MAC/WWN/GUID and SAS Addresses
107
Basic Information
107
Looking for the MAC Address of a LAN Controller
107
Looking for the WWN Address of a Fibre Channel Controller
108
Looking for SAS Addresses of SAS Controllers for External Devices
109
Looking for the GUID Address of an Infiniband Controller
109
Using the Chassis ID Prom Tool
110
Configuring LAN Teaming
113
Switching off the ID Indicator
114
Performing a Fan Test
115
Updating the Golden Image
117
Updating the Golden Image for Irmc S5 Firmware
117
Updating the Golden Image for BIOS Firmware
118
Power Supply Unit (PSU)
121
Safety Notes
121
Basic Information
121
Redundant Power Supply
124
Installing a Hot-Plug PSU
124
Removing a Hot-Plug PSU
127
Replacing a Hot-Plug PSU
130
Hard Disk Drive (HDD) / Solid State Disk (SSD)
133
Safety Notes
133
Basic Information
134
Handling Hdds or Ssds Without Installation Frame
136
Inch HDD and 3.5-Inch Installation Frame
136
Inch HDD/SSD and 2.5-Inch Installation Frame
137
Inch HDD/SSD and 3.5-Inch Installation Frame
139
EDSFF SSD and EDSFF Installation Frame
141
Inch HDD Configurations
143
Overview of Configurations
143
Configuration with up to 10 HDD Modules
143
Configuration with up to 12 HDD Modules
144
Installing 3.5-Inch HDD Modules
145
Removing 3.5-Inch HDD Modules
148
Replacing a 3.5-Inch HDD Module
150
Replacing the 10X 3.5-Inch HDD Backplane
152
Replacing the 12X 3.5-Inch HDD Backplane
155
2.5-Inch HDD/SSD Configurations
159
Overview of Configurations
159
Configuration with up to 16 HDD/SSD Modules
159
Configuration with up to 24 Hdd/Ssd/Pcie SSD Modules
160
Configuration with up to 24 Pcie SSD Modules
162
Configuration with Rear 2.5-Inch Hdd/Ssd/Pcie Modules
164
Installing 2.5-Inch HDD/SSD Modules
165
Removing 2.5-Inch HDD/SSD Modules
168
Replacing a 2.5-Inch HDD/SSD Module
171
Installing 2.5-Inch Pcie SSD Modules
172
Removing 2.5-Inch Pcie SSD Modules
175
Replacing a 2.5-Inch Pcie SSD Module
178
Replacing a 8X 2.5-Inch HDD Backplane
179
Concluding Steps
183
On Page
183
Replacing a 24X 2.5-Inch HDD Backplane and a Switch Board
184
EDSFF SSD Configurations
188
Overview of Configurations
188
Installing EDSFF SSD Modules
191
If Applicable, "Installing the Front Cover with Lock" on Page
193
If Applicable, "Switching on the Server" on Page
193
If Applicable, Rescan Available Devices from Your os
193
Removing EDSFF SSD Modules
193
If Applicable, "Removing the Front Cover with Lock" on Page
194
Shutting down the Server" on Page
194
Replacing an EDSFF SSD Module
195
Replacing a 16X EDSFF SSD Backplane (Top)
197
Replacing a 16X EDSFF SSD Backplane (Bottom)
201
Installing the SAS Expander Board
204
SAS Expander Board
204
Removing the SAS Expander Board
208
Replacing the SAS Expander Board
210
Positions of Rear HDD Cages
212
Rear HDD/SSD Extension Box
212
Upgrading with Rear HDD Cage 1
212
Caution
213
After Installing or Removing an Additional Backplane, Never Forget to
217
Change the System Information Using the Chassis ID Prom Tool
217
For more Information, See the "Serverview Suite RAID
217
Management" User Guide
217
Preliminary Steps
217
RAID Array
217
Upgrading with Rear HDD Cage 2
217
Replacing a Rear 4X 2.5-Inch HDD Backplane
221
Replacing a Rear 2X 2.5-Inch HDD Backplane
224
Basic Information
227
Fans
227
Safety Notes
227
Replacing a Fan Module
229
Expansion Cards and Backup Units
233
Safety Notes
233
Basic Information
234
Handling Slot Brackets
237
Installing Slot Brackets
237
Handling SFP+ Transceiver Modules
239
Installing SFP+ Transceiver Modules
239
Removing Slot Brackets
239
Removing SFP+ Transceiver Modules
245
Installing an OCP Module
249
OCP (Open Compute Project) Modules
249
Position of the OCP Module
249
Removing an OCP Module
252
Replacing the OCP Module
254
Expansion Cards in Standard Pcie Slots
255
Installing an Expansion Card
255
Removing an Expansion Card
262
Replacing an Expansion Card
265
Installing an Internal RAID Riser Module
267
Internal RAID Riser Module
267
Removing an Internal RAID Riser Module
273
Replacing an Internal RAID Riser Module
277
Replacing a Riser Card
278
Expansion Cards in Riser Modules
280
Installing an Expansion Card in a Riser Module
280
Removing an Expansion Card from a Riser Module
284
Replacing Expansion Cards from a Riser Module
286
Replacing a Riser Card
288
GPU Cards in Riser Modules
291
Installing a GPU Card in a Riser Module
291
Removing a GPU Card from a Riser Module
307
Replacing a GPU Card from a Riser Module
312
Replacing a Riser Card
314
Flash Backup Unit (FBU)
316
Positions of the Fbus
316
Installing an FBU
317
Removing an FBU
324
Replacing an FBU
325
Main Memory
329
Safety Notes
329
Basic Information
330
Slots and Features
330
General Memory Population Rules
332
DDR4 Only - Memory Population Rules
333
DDR4 and Optane Pmem - Memory Population Rules
334
Installing Memory Modules
336
Removing Memory Modules
340
Replacing Memory Modules
341
Handling Memory Dummy Modules
343
Processor (CPU)
345
Safety Notes
345
Basic Information
346
Upgrading to 2 Cpus Configuration
348
Replacing a CPU or Heat Sink
359
Liquid Cooling (LC)
367
Safety Notes
367
Basic Information
368
Replacing the CPU for LC Device
369
Accessible Drives
385
Basic Information
385
Safety Notes
385
Installing the ODD (2.5-Inch Chassis)
387
Optical Disk Drive (ODD)
387
Storing the ODD Latch
387
Removing the ODD (2.5-Inch Chassis)
390
Replacing the ODD (2.5-Inch Chassis)
394
Installing the ODD (3.5-Inch Chassis)
395
Removing the ODD (3.5-Inch Chassis)
402
Replacing the ODD (3.5-Inch Chassis)
409
Installing the LTO Drive
411
LTO Drive
411
Removing the LTO Drive
419
Replacing the LTO Drive
426
Installing the RDX Drive
428
RDX Drive
428
Removing the RDX Drive
437
Replacing the RDX Drive
445
Basic Information
447
Front Panel
447
Safety Notes
447
Common Operation Panel (COP)
448
Replacing the COP
448
Front VGA
454
Installing the Front VGA
454
Removing the Front VGA
457
Replacing the Front VGA
460
Additional Interfaces
463
Installing the Serial Interface
463
Safety Notes
463
Serial Interface
463
Removing the Serial Interface
467
Replacing the Serial Interface
469
Rear VGA Connector
470
Replacing the Rear VGA
470
Basic Information
475
Safety Notes
475
System Board and Components
475
CMOS Battery
476
Replacing the CMOS Battery
476
Position of the TPM
479
TPM Kit
479
Trusted Platform Module (TPM)
479
Installing the TPM
480
Removing the TPM
483
Replacing the TPM
488
Installing the Irmc Microsd Card
491
Irmc Microsd Card
491
Note for Embedded Lifecycle Management (Elcm)
491
Removing the Irmc Microsd Card
493
Replacing the Irmc Microsd Card
494
M.2 Ssd
497
Slots and Bolts for M.2 Ssds
497
Installing an M.2 SSD
498
Removing an M.2 SSD
502
Replacing an M.2 SSD
504
Dual Microsd 64GB Enterprise
505
Installing the Dual Microsd 64GB Enterprise
505
Position of the Dual Microsd 64GB Enterprise
505
Removing the Dual Microsd 64GB Enterprise
509
Replacing the Dual Microsd 64GB Enterprise
512
Replacing the Microsd Card
514
Installing the VROC Module
516
VROC Module
516
Removing the VROC Module
517
Replacing the VROC Module
519
Replacing the System Board
520
System Board
520
Inch HDD Configuration
535
Mechanical Overview
535
Server Front
535
Inch HDD/SSD Configuration
536
EDSFF SSD Configuration
537
Server Rear
537
Servers with Air Cooling
537
Servers with Liquid Cooling
539
Server Interior
540
Servers with Air Cooling
540
Servers with Liquid Cooling (LC)
541
Connectors and Indicators
542
Connectors and Indicators on the System Board
542
System Board D3891
542
Connectors on the Front Panel
548
Server Front
548
Indicators on the COP
549
States of Power-On Indicator and Time Duration During Firmware Restore
552
Indicator on the ODD
556
System Cabling Overview - English
573
Sysboardconn
578
Basic 10X/12X3.5" or 16X/24X2.5" or 64Xedsff
579
Basic ODD/VGA 10X3.5"/16X2.5
580
Basic Serial
581
Basic LTO 16X2.5
582
Basic RDX 16X2.5
583
Basic OOB 10X3.5
584
Basic OOB 12X3.5
585
Basic OOB 16X2.5
586
Basic OOB 24X2.5" Nvme MIX
587
Basic OOB 24X2.5" Nvme
588
Basic OOB 64Xedsff
589
Basic OOB Rear 4X2.5
590
Basic OOB Rear 2X2.5
591
Basic OOB Expander Board_40 12X3.5"/16X2.5"/24X2.5" Nvme MIX
592
Power 10X3.5
593
Power 12X3,5
594
Power 16X2.5
595
Power 24X2.5" Nvme MIX
596
Power 24X2.5" Nvme
597
Power 64Xedsff
598
Power Expander Board_40 12X3.5"/16X2.5"/24X2.5" Nvme MIX
599
Power Rear 4X2.5
600
Power Rear 2X2.5
601
Power Internal RAID Riser
602
Power GPU A40/A6000/A100
604
Data FBU Ep5/6X0I/Ep5/6X0E
605
Data Hddactivity EP 5/6Xxi
606
Data Hddactivity CP 500I
607
Data Internal RAID Riser
608
PYR2546R3N(TYPE1-1):Data 8Xsata 3.5" Onboard
609
PYR2546R3N(TYPE1-2):Data 8Xsas/Sata 3.5" Cp/Ep5Xxi
610
PYR2546R3N(TYPE1-3A):Data 10Xsas/Sata 3.5" Ep5X0I
611
PYR2546R3N(TYPE1-3B):Data 10Xsas/Sata 3.5" Ep6X0I
612
PYR2546RAN(TYPE2-1A):Data 12Xsas/Sata 3.5" Ep5X0I
613
PYR2546RAN(TYPE2-1B):Data 12Xsas/Sata 3.5" Ep6X0I
614
PYR2546RBN(TYPE2-5):Data 12Xsas/Sata 3.5" Expander (CP/EP 5Xxi)
615
PYR2546R2N/PYR2546RCN(TYPE3-1):Data 8Xsata 2.5"Onboard
616
PYR2546R2N/PYR2546RCN(TYPE3-2):Data 8Xsas/Sata 2.5" CP/ Ep5Xxi
617
PYR2546R2N/PYR2546RCN(TYPE3-3A):Data 16Xsas/Sata 2.5" Ep5X0I
618
PYR2546R2N/PYR2546RCN(TYPE3-3B):Data 16Xsas/Sata 2.5" Ep6X0I
619
PYR2546R2N/PYR2546RCN+PYBBA24PF/PY-BA24PF(TYPE3- 5A):Data 8Xsata 2.5" Onboard+Rear 4Xnvme (Ep5X0I)
621
PYR2546R2N/PYR2546RCN+PYBBA24PF/PY-BA24PF(TYPE3- 5B):Data 8Xsata 2.5" Onboard+Rear 4Xnvme (Ep6X0I)
622
PYR2546R2N/PYR2546RCN+PYBBA24PF/PY- BA24PF+PYBBA22P2/PY-BA22P2(TYPE3-6):Data 8Xsas/Sata 2.5" Cp/Ep5Xxi+Rear 4X/6X Nvme (Retimer)
623
PYR254 6R2N/PYR2546RCN +PYBBA24PF/PY-BA24PF+PYBBA22P2 /PY-BA22P2(TYP E3-8): Data 16Xsas/Sata 2.5" Dual RAID (Cp/Ep5Xxi) X2+Rear 4X/6X Nvme (Retimer)
624
PYR2546R2N/PYR2546RCN+PYBBA24PF/PY-BA24PF(TYPE3- 9A):Data 16Xsas/Sata 2.5"+Rear 4Xnvme (Ep5X0I)X2
625
PYR2546R2N/PYR2546RCN+PYBBA24PF/PY-BA24PF(TYPE3- 9C):Data 16Xsas/Sata 2.5"+Rear 4Xnvme (Ep6X0I)
626
PYR2546R2N/PYR2546RCN+PYBBA24PF/PY-BA24PF(TYPE3- 9B):Data 16Xsas/Sata 2.5"+Rear 4Xnvme (Ep6X0I)X2
627
PYR2546R2N/PYR2546RCN+PYBBA24PF/PY-BA24PF(TYPE3- 9D):Data 16Xsas/Sata 2.5"+Rear 4Xnvme (Ep5X0I)
628
PYR2546R2N/PYR2546RCN+PYBBA24PF/PY- BA24PF+PYBBA22P2/PY-BA22P2(TYPE3-10A):Data 16Xsas/ SATA 2.5" (Ep5X0I)+Rear 4X/6X Nvme (Retimer)
629
PYR2546R2N/PYR2546RCN+PYBBA24PF/PY- BA24PF+PYBBA22P2/PY-BA22P2(TYPE3-10B):Data 16Xsas/ SATA 2.5" (Ep6X0I)+Rear 4X/6X Nvme (Retimer)
630
PYR2546RDN/PYR2546REN(TYPE3-11):Data 16Xsas/Sata 2.5" Expander(Cp/Ep5Xxi)
631
PYR254 6RDN/PYR2 546REN+PYBBA2 4S3/P Y-BA24S3+PYBBA22S4/PY-BA22S4(TYPE3-12):Data 16Xsas/Sata 2.5" Expander(CP /Ep5Xxi)+Rear 4Xsas/Sata 2.5" Expander
632
PYR254 6RDN/PYR2 546REN+PYBBA2 4PF/P Y-BA24PF+PYBBA22P2 /PY-BA22P2(TYP E3-13):Data 16Xsas/Sata 2.5" Expander(CP /Ep5Xxi)+Rear 4X/6X Nvme (Retimer)
633
PYR2546RFN(TYPE4-1):Data 24Xsas/Sata 2.5" (Cp/Ep5Xxi)X3
634
PYR2546RFN(TYPE4-2A):Data 24Xsas/Sata 2.5" (Ep5X0I)X2
635
PYR2546RFN(TYPE4-2B):Data 24Xsas/Sta 2.5" (Ep6X0I)X2
636
PYR2546RFN+PYBBA24S3/PY-BA24S3+PYBBA22S4/PY- BA22S4(TYPE4-3A):Data 24Xsas/Ata 2.5"+Rear 4Xsas/Sata 2.5" (Ep5X0I)X2
637
PYR2546RFN+PYBBA24S3/PY-BA24S3+PYBBA22S4/PY- BA22S4(TYPE4-3B):Data 24Xsas/Sata 2.5"+Rear 4Xsas/Sata 2.5" (Ep6X0I)X2
638
PYR2546RFN+PYBBA24PF/PY-BA24PF+PYBBA22P2/PY- BA22P2(TYPE4-4A):Data 24Xsas/Sata 2.5" (Ep5X0I)X2+Rear 4X/ 6X Nvme (Retimer)
639
PYR2546RFN+PYBBA24PF/PY-BA24PF+PYBBA22P2/PY- BA22P2(TYPE4-4B):Data 24Xsas/Sata 2.5" (Ep6X0I)X2+Rear 4X/ 6X Nvme (Retimer)
640
PYR2546RFN(TYPE4-5):Data 8X2.5" SATA Onboard+8X2.5" Nvme Onboard
641
PYR2546RFN(TYPE4-6):Data 8Xsas/Ata 2.5" (Cp/Ep5Xxi)+8X2.5" Nvme Onboard
642
PYR2546RFN(TYPE4-7):Data 16Xsas/Sata 2.5" (CP/ Ep5Xxi)X2+8X2.5" Nvme Onboard
643
PYR2546RFN+PYBBA24PF/PY-BA24PF+PYBBA22P2/PY- BA22P2(TYPE4-8):Data 16Xsas/Sata 2.5" (Cp/Ep5Xxi)X2+8X2.5" Nvme Onboard+Rear 4X/6X Nvme (Retimer)
644
PYR2546RFN(TYPE4-9A):Data 16Xsas/Sata 2.5" (Ep5X0I)+8X2.5" Nvme Onboard
645
PYR2546RFN(TYPE4-9B):Data 16Xsas/Sata 2.5" (Ep6X0I)+8X2.5" Nvme Onboard
646
PYR2546RFN+PYBBA24PF/PY-BA24PF+PYBBA22P2/PY- BA22P2(TYPE4-10A):Data 16Xsas/Sata 2.5" +8X2.5" Nvme Onboard+Rear 4Xnvme (Ep5X0I)X2
647
PYR2546RFN+PYBBA24PF/PY-BA24PF+PYBBA22P2/PY- BA22P2(TYPE4-10C):Data 16Xsas/Sata 2.5" +8X2.5" Nvme Onboard+Rear 4Xnvme (Ep6X0I)
648
PYR2546RFN+PYBBA24PF/PY-BA24PF+PYBBA22P2/PY- BA22P2(TYPE4-10B):Data 16Xsas/Sata 2.5"+8X2.5" Nvme Onboard+Rear 4Xnvme (Ep6X0I)X2
649
PYR2546RFN+PYBBA24PF/PY-BA24PF+PYBBA22P2/PY- BA22P2(TYPE4-10D):Data 16Xsas/Sata 2.5"+8X2.5" Nvme Onboard+Rear 4Xnvme (Ep5X0I)
650
PYR2546RFN+PYBBA24PF/PY-BA24PF+PYBBA22P2/PY- BA22P2(TYPE4-11A):Data 16Xsas/Sata 2.5" (Ep5X0I)+8X2.5" Nvme Onboard+Rear 4X/6X Nvme (Retimer)
651
PYR2546RFN+PYBBA24PF/PY-BA24PF+PYBBA22P2/PY- BA22P2(TYPE4-11B):Data 16Xsas/Sata 2.5" (Ep6X0I)+8X2.5" Nvme Onboard+Rear 4X/6X Nvme (Retimer)
652
PYR2546RGN(TYPE4-12):Data 24Xsas/Sata 2.5" Expander(CP/ Ep5Xxi)
653
PYR2546RGN+PYBBA24S3/PY-BA24S3+PYBBA22S4/PY- BA22S4(TYPE4-13):Data 24Xsas/Sata 2.5" Expander(CP/ Ep5Xxi)+Rear 4X/6X 2.5" (Expander)
654
PYR2546RGN+PYBBA24S3/PY-BA24S3+PYBBA22S4/PY- BA22S4(TYPE4-15A):Data 24Xsas/Sata 2.5" Expander+Rear 4X/ 6X 2.5"(Ep5X0I)
655
PYR2546RGN+PYBBA24S3/PY-BA24S3+PYBBA22S4/PY- BA22S4(TYPE4-15B):Data 24Xsas/Sata 2.5" Expander+Rear 4X/ 6X 2.5"(Ep6X0I)
656
PYR2546RGN+PYBBA24PF/PY-BA24PF+PYBBA22P2/PY- BA22P2(TYPE4-16):Data 24Xsas/Sata 2.5" Expander(CP/ Ep5Xxi)+Rear 4X/6X Nvme (Retimer)
657
PYR2546RGN+PYBBA24S3/PY-BA24S3+PYBBA22S4/PY- BA22S4(TYPE4-17):Data 16Xsas/Sata 2.5" Expander(CP/ Ep5Xxi)+8Xnvme Onboard+Rear 4X/6X 2.5" (Expander)
658
PYR2546RGN+PYBBA24S3/PY-BA24S3+PYBBA22S4/PY- BA22S4(TYPE4-18A):Data 16X2.5" Expander(Rear Ep5X0I Only)+8Xnvme Onboard+Rear 4X/6X 2.5" (Rear Ep5X0I Only)
659
PYR2546RGN+PYBBA24S3/PY-BA24S3+PYBBA22S4/PY- BA22S4(TYPE4-18B):Data 16Xsas/Sata 2.5" Expander+8Xnvme Onboard+Rear 4X/6X 2.5" (Ep6X0I)
660
PYR2546RGN+PYBBA24PF/PY-BA24PF+PYBBA22P2/PY- BA22P2(TYPE4-19):Data 16Xsas/Sata 2.5" Expander(CP/ Ep5Xxi)+8Xnvme Onboard+Rear 4X/6X Nvme (Retimer)
661
PYR2546RHN(TYPE5-1):Data 24Xnvme (Switch Board)
662
PYR2546RHN+PYBBA24S3/PY-BA24S3+PYBBA22S4/PY- BA22S4(TYPE5-2A):Data 24Xnvme (Switch Board)+Rear 4X/6X 2.5"(Rear Cp/Ep5Xxi)
663
PYR2546RHN+PYBBA24S3/PY-BA24S3+PYBBA22S4/PY- BA22S4(TYPE5-2B):Data 24Xnvme (Switch Board)+Rear 4X/6X 2.5"(Rear Ep6X0I)
664
PYR2546RHN+PYBBA24PF/PY-BA24PF+PYBBA22P2/PY- BA22P2(TYPE5-3):Data 24Xnvme (Switch Board)+Rear 4X/6X Nvme (Retimer Card)
665
Pyr2546R6N(Type6):Data 64Xedsff
666
Data Dual Microsd 64GB Enterprise
667
Fujitsu PRIMERGY RX2540 M6 Operating Manual (121 pages)
Brand:
Fujitsu
| Category:
Server
| Size: 1.85 MB
Table of Contents
Table of Contents
7
Introduction
13
Concept and Target Groups of this Manual
13
Notational Conventions
13
Before You Start
15
Safety Notes
15
Documentation Overview
15
About Availability of Manuals
15
List of Documents
16
Product Description
19
Overview of the Server
19
Server Front
19
Inch HDD Configuration
19
Inch HDD/SSD Configuration
20
EDSFF SSD Configuration
21
Server Rear
21
Servers with Air Cooling
21
Servers with Liquid Cooling
23
Features
23
Customer Self Service (CSS)
23
System Board
24
Trusted Platform Module (TPM)
24
Power Supply Unit (PSU)
25
Advanced Thermal Design (ATD)
26
Configuration Thermal Design (CTD)
26
High Level of Availability and Data Security
27
Irmc S5 with Integrated Management LAN Connector
27
Server Management
28
Serverview Installation Manager
29
Service and Support
29
ISM Remote Management
30
Serverview Remote Management
30
Property and Data Protection
31
BIOS Setup Security Functions
31
Connectors, Controls, and Indicators
32
Server Front
32
Connectors on the Front Panel
32
Controls on the COP
33
Indicators on the Server Front
34
Server Rear
39
Connectors on the Server Rear
39
ID, CSS and Global Error Indicators
41
LAN Indicators
43
Indicator on Hot-Plug PSU
45
Important Information
47
Introduction
47
Safety Instructions
47
Basic Safety Instructions
47
Before Starting up
48
Installation and Operation
48
Batteries
51
Working with Optical Disk Drives (Odds) and Media
51
Laser Information
53
Modules with Electrostatic-Sensitive Devices (ESD Modules)
53
Transporting the Server
55
Installing the Server in the Rack
56
Other Important Information
56
CE Conformity
57
Energy Star
57
FCC Class a Compliance Statement
58
Environmental Protection
59
Starting up
61
Safety Notes
61
Installation Steps, Overview
61
Unpacking the Server
63
Installing the Server in the Rack
64
Overview
64
Installing the Server in the Rack
65
Sliding the Server into the Rack
68
Connecting Cables
69
Notes on Connecting/Disconnecting Cables
69
Connecting Devices to the Server
70
Connecting the Liquid Cooling (LC) to the External Cooling Environment (Special Release)
71
Connecting the Power Cord
72
Overview
72
Connecting the Power Cord (AC PSU)
73
Connecting the Power Cord (DC PSU)
74
Switching on the Server for the First Time
77
Installing the Front Cover with Lock
78
Configuring the Server with Serverview Installation Manager
78
Configuring the Server Without Serverview Installation Manager
80
Notes on Configuring Controllers
80
General Notes
80
Notes on Onboard SATA Controllers
81
Notes on SAS/SATA RAID Controllers
81
Note on Operating System
81
Operation
83
Safety Notes
83
Removing and Installing the Front Cover with Lock
83
Switching the Server on and off
84
Installing HDD/SSD Modules
87
Installing 3.5-Inch HDD Modules
87
Installing 2.5-Inch HDD/SSD Modules
89
Installing EDSFF SSD Modules
91
Installing a Second PSU
93
Cleaning the Server
96
Troubleshooting and Tips
97
General Proceeding
97
Power-On Indicator Remains Unlit after You Have Switched on Your Device
98
System Does Not Boot after Installing a New HDD
98
Screen Remains Blank
99
No Screen Display or Display Drifts
99
Server Switches Itself off
100
No Mouse Pointer Displayed on Screen
100
No Effect of Keyboard or Mouse
100
Time And/Or Date Is Incorrect
101
Temperature Warning
101
Added Drive Reported as Defective
102
Expansion Cards or Onboard Devices Not Recognized
102
ODD Cannot Read Data
103
Technical Data
105
Data Sheets
105
System Board
105
Processor (CPU)
105
Memory Modules Configuration
106
Interfaces
106
Onboard or Integrated Controllers
108
Slots
109
Drive Bays
110
Dimension/Weight
110
Ventilation Clearance
110
Ambient Conditions
111
Noise Level
111
Electrical Values of the AC Psus
112
Electrical Values of the DC PSU -48
115
Electrical Values of the HVDC PSU
116
Electrical Values of the System
116
Compliance with Standards
118
Related Products
Fujitsu PRIMERGY RX2540 M1
Fujitsu PRIMERGY RX2540 M4
Fujitsu PRIMERGY RX2540 M2
Fujitsu PRIMERGY RX2540 M5
Fujitsu PRIMERGY RX2540 M7
Fujitsu PRIMERGY RX2530 M2
Fujitsu PRIMERGY RX2560 M2
Fujitsu PRIMERGY RX2520 M5
Fujitsu PRIMERGY RX2530 M5
Fujitsu PRIMERGY RX2530 M4
Fujitsu Categories
Air Conditioner
Laptop
Server
Scanner
Storage
More Fujitsu Manuals