Technical Data - Bosch Rexroth VT-HNC100 3X/S Series Technical Data Manual

Digital drive controller for hydraulic axes with sercos interface.
Hide thumbs Also See for Rexroth VT-HNC100 3X/S Series:
Table of Contents
Technical data VT-HNC100-C-3X/S (Compact)
Operating voltage
1)
Current consumption at 24 VDC
Processor
Analog inputs (AI):
– Voltage input (reference to AGND - Analog ground)
• Channel number
• Input voltage
• Input resistance
• Resolution
• Non-linearity
2)
• Calibration tolerance
– Current inputs
• Channel number
• Input current
• Leakage current
• Resolution
– Voltage supply for analog sensors
via the VT-HNC100-C-3X/S
Analog outputs (AO):
– Voltage outputs
• Channel number
• Output voltage
• Output current
• Load
– Resolution
– Non-linearity
• In the range –9.5 V to +9.5 V
• In the range –10 V to –9.5 V and +9.5 V to +10 V
1)
If a 24 V transducer supply is implemented directly via the
VT-HNC100...3X/S (supply voltage is looped in), the transducer
specification has to be observed.
2)
If the factory settings are insufficient, the measurement technol-
ogy can be calibrated on site via software in a system-specific way.
Digital drive controller | VT-HNC100.../S
U
18 to 30 VDC
B
Approx. 200 mA (observe additional current consumption for con-
nected sensors/actuators)
32 bit power PC
1
U
Max. +12 V to –12 V (+10 V to –10 V measurable)
E
R
200 kΩ ± 5 %
E
5 mV
< 0.2 %
Max. 40 mV (with factory settings)
2
I
4 mA to 20 mA
E
I
0.1 to 0.4 % (with 100 Ω between pin 2 and/or pin 3 (Cin1+ and/or
V
Cin2+) and "AGND"
5 μA
U, I U
, max. 100 mA at X2A, pin 7 (+24 Vsens)
B
2
U
–10 V to +10 V (max. –10.7 V to +10.7 V)
nom
I
±10 mA
max
R
1 kΩ
min
1.25 mV
< 0.1 %
< 0.2 %
RE 30159, edition: 2012-03, Bosch Rexroth AG