▶ Component series 3X H7644 Contents Features Ordering code Software project planning Overview of the controller functions System overview System overview, interfaces Technical data Pin assignment Unit dimensions Project planning / maintenance instructions / additional information RE 30159, edition: 2012-03, Bosch Rexroth AG...
– EnDat 2.2 – Analog 0 to ±10 V ▶ Actuating variable output voltage or current ▶ Freely confi gurable controller variants – Position / force / velocity controller – Substitutional closed-loop control (position/force) Bosch Rexroth AG, RE 30159, edition: 2012-03...
HD connector and open breakout cable for VT-HNC100-1-3X Cable set VT17220-1X/HNC100-3X length 2 m, R901189302 for analog signals (connection X2A) or digital position measurement systems (connection X8M) with FK-MC connector and open breakout cable for VT-HNC100-C-3X RE 30159, edition: 2012-03, Bosch Rexroth AG...
▶ Dynamic following error monitoring – Force, ▶ Traversing range limits (electronic end switches) – Position ▶ Cable break monitoring for position transducers ▶ Command value feedforward ▶ Cable break monitoring for sensors with out- put 4 to 20 mA Bosch Rexroth AG, RE 30159, edition: 2012-03...
VT-HNC100...3X/S (supply voltage is looped in), the transducer specification has to be observed. If the factory settings are insufficient, the measurement technol- ogy can be calibrated on site via software in a system-specific way. RE 30159, edition: 2012-03, Bosch Rexroth AG...
Page 8
440 g CE conformity See page 2 Further technical details upon request. Notice: For information on the environment simulation testing for the areas EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30139-U. Bosch Rexroth AG, RE 30159, edition: 2012-03...
Page 9
If the factory settings are insufficient, the measurement technol- VT-HNC100-1-3X/S (supply voltage is looped in), the transducer ogy can be calibrated on site via software in a system-specific way. specification has to be observed. Configurable as current or voltage output. RE 30159, edition: 2012-03, Bosch Rexroth AG...
Page 10
For information on the environment simulation testing for the areas EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30139-U. If the factory settings are insufficient, the measurement technology can be calibrated on site via software in a system- specific way. Bosch Rexroth AG, RE 30159, edition: 2012-03...
Page 11
AIO (Analog) Shield X7S1 sercos II 24 Vsens Vout1 + X7S2 Vout2 + Vin 1 HNC100 Cin2 + Cin1 + AGND Notice: The pins marked with "reserved" are reserved and must not be connected! RE 30159, edition: 2012-03, Bosch Rexroth AG...
Cout1 Notices: +24 Vsens The pins marked with X7P/C X2A1 Reserved "reserved" are reserved and must not be connected! HNC100 PROFIBUS DP or CANopen (connection X7P/C) are not available with the ser- cos version. Bosch Rexroth AG, RE 30159, edition: 2012-03...
3.3V RUN BUS X7S1 X7S2 HNC100 VT-HNC100-1-3X/S... Assembly on top hat rail TH 35-7.5 or TH 35-15 according to EN 60715 slot1 X8M 1 X7E2 18-30V 3.3V RUN BUS X2D1 X7E1 X7P/C X2A1 HNC100 RE 30159, edition: 2012-03, Bosch Rexroth AG...