Fault
Code Designation Response
(P)
98
CRC fault
Immediate
stop
99
IPOS ramp
Immediate
calculation
stop
100
Vibration –
Display fault
warning
(P)
101
Vibration fault Rapid stop
(P)
102
Oil aging
Display fault
warning
(P)
103
Oil aging fault Display fault
(P)
104
Oil aging –
Display fault
overtemperat-
(P)
ure
105
Oil aging
Display fault
ready signal
(P)
106
Brake wear
Display fault
(P)
107
Line compon-
Immediate
ents
stop
108
DCS fault
Display fault 0
Subfault
Code
Designation
0
"CRC via internal flash"
fault
0
"Ramp calculation" fault
0
Vibrations diagnostics
warning
0
Vibration diagnostics fault Vibration sensor signals fault
0
Oil aging warning
0
Oil aging fault
0
Oil aging overtemperature Overtemperature signal from
0
Oil aging ready signal
0
Brake wear fault
1
For regenerative power
supply only: No feedback
signal from main contactor
DCS fault
1
Configuration data not
loaded correctly to DCS..B
option.
2
Invalid configuration data
for software version of the
DCS..B option.
3
Unit was programmed with
incorrect software inter-
face.
4
Incorrect reference voltage • Incorrect reference voltage
5
6
Faulty system voltage
7
10
Incorrect supply voltage.
Fault messages and list of faults
Possible cause
Internal device fault flash
memory defective.
PLUS®
Only in IPOS
mode:
Positioning ramp is sinusoidal
or square and an attempt is
made to change ramp times
and traveling velocities with en-
abled inverter.
Vibration sensor warning (→
"DUV10A" operating instruc-
tions)
Warning signal from the oil
aging sensor
Fault message from the oil
aging sensor
the oil aging sensor
Oil aging sensor is not ready
for operation
Brake lining worn
Main contactor defective
Connection interrupted while
loading the program to the
DCS..B option.
DCS..B option configured using
a wrong software version.
Program or configuration data
was loaded into the unit with an
®
incorrect MOVISAFE
software.
• Faulty supply voltage of the
DCS..B option
• Faulty component on the
DCS..B option
• Faulty supply voltage of the
DCS..B option
• Faulty component on the
DCS..B option
• DC 24 V supply voltage of
the DCS..B option is faulty.
• Faulty component on the
DCS..B option
System Manual – MOVIDRIVE
Service
Measure
Sending in a device for repair
PLUS®
Rewrite the IPOS
pro-
gram so that ramp times and
traveling velocities can only
be altered when the inverter is
inhibited.
Determine cause of vibra-
tions. Continue operation until
F101 occurs.
SEW‑EURODRIVE recom-
mends that you remedy the
cause of the vibrations imme-
diately
Schedule oil change
SEW-EURODRIVE recom-
mends that you change the
gear unit oil immediately.
• Let oil cool down
• Check if the gear unit cools
properly
• Check voltage supply of oil
aging sensor
• Check and, if necessary,
replace the oil aging sensor
Replace brake lining (→ "Mo-
tors" operating instructions).
• Check main contactor
• Check control cables.
• Reload the configuration
files.
• Then switch the DCS..B op-
tion off and on again.
• Configure the DCS..B op-
tion with the permitted
®
MOVISAFE
software ver-
sion.
• Then switch the DCS..B op-
tion off and on again.
• Check the DCS..B version
and parameterize it again
®
using a valid MOVISAFE
software.
• Then switch the DCS..B op-
tion off and on again.
• Check supply voltage of
DCS..B option.
• Switch DCS..B option off
and on again.
• Check supply voltage of
DCS..B option.
• Switch DCS..B option off
and on again.
• Check supply voltage of
DCS..B option.
• Switch DCS..B option off
and on again.
®
MDX60B/61B