Parameters
8
Explanation of the parameters
P27. Process controller input values
P270 Setpoint source
P271 Setpoint
P272 IPOS setpoint address
P273 Time constant
P274 Scaling setpoint
P275 Actual value source
P276 IPOS actual value address
P277 Scaling actual value
248
System Manual – MOVIDRIVE
Setting range: Parameters/IPOS variable/Analog 1/Analog 2
This parameter is used to set the source from which the setpoint should be read.
Setting range: -32767 – 0 – 32767
If P270  (→ 2 248) is set to "Parameter", the value of the parameter P271 is used as
the setpoint. P271 and the IPOS variable H546 are identical.
Setting range: 0 – 1023
If P270  (→ 2 248) is set to "IPOS variable", the address of the variable to be used is
stored in P271  (→ 2 248). P272 and the IPOS variable H547 are identical.
Setting range: 0 – 0.01 – 2000 s
This parameter is used to set the ramp for the setpoint ramp generator (reference
15000 units).
Time constant T
setpoint
Setting range: -32,767 – 1 – 32,767
Factor for scaling the setpoint. P274 and the IPOS variable H548 are identical.
Setting range: Analog 1/analog 2/IPOS variable
This parameter is used to set the source from which the actual value should be read.
Setting range: 0 – 1023
If P275  (→ 2 248) is set to "IPOS variable", the address of the variable to be used is
stored in P276. P276 and the IPOS variable H549 are identical.
Setting range: -32,767 – 1 – 32,767
Scaling factor of the filtered actual value. P277 and the IPOS variable H550 are
identical.
®
MDX60B/61B
= 0 → ramp is deactivated.