Technical data of options
4

CAN/CANopen DFC11B fieldbus interface

4.19
CAN/CANopen DFC11B fieldbus interface
4.19.1
Part number
4.19.2
Description
4.19.3
Electronics data
DFC11B option
Communication profile
Number of process data words
Baud rate
Connection technology
Permitted cable cross section X31
(CAN bus connection)
Terminating resistor
Addressing
Tools for startup
118
System Manual – MOVIDRIVE
08243174
®
The MOVIDRIVE
MDX61B drive inverter in conjunction with the DFC11B option al-
lows connection to higher-level automation, project planning and visualization systems
via the open and standardized CANopen fieldbus system thanks to the option's high-
performance universal fieldbus interface. You can also access parameters and pro-
cess data using the MOVILINK
SEW‑EURODRIVE.
The DFC11B fieldbus interface can be plugged into the fieldbus slot. in this way, a
second system bus (CAN) on MOVIDRIVE
enables communication with the higher-level controller for a maximum of 10 process
data. You need an EDS file to be able to integrate the DFC11B in the higher-level
CANopen control. You can download this file from the SEW‑EURODRIVE website.
• SEW-MOVILINK
• CANopen
• CAN Layer 2
1 – 10 process data words
Setting using parameter P894:
125 kBaud/250 kBaud/500 kBaud/1 MBaud
9-pole D-sub connector X30 (pin assigned to CIA standard) or terminal X31
One core per terminal: 0.20 – 2.5 mm
Two cores per terminal: 0.25 – 1 mm
120 Ω (set using DIP switch S1-R)
Setting via parameter P891 (SBus MOVILINK
• MOVITOOLS
• DBG60B keypad
®
MDX60B/61B
®
protocol designed especially for devices from
®
is made available. The DFC11B option
®
2
(AWG24 – 12)
2
(AWG22 – 17)
®
) or P896 (CANopen)
®