13.16 Connecting Encoders And Resolvers - SEW-Eurodrive MOVIDRIVE MDX61B System Manual

Hide thumbs Also See for MOVIDRIVE MDX61B:
Table of Contents

13.16 Connecting encoders and resolvers

INFORMATION
Folgen
The following wiring diagrams do not show the view onto the cable end but the
view onto the connection to motor or MOVIDRIVE
The core colors specified in the wiring diagrams are in accordance with IEC 757
and correspond to the core colors used in the prefabricated cables from
SEW‑EURODRIVE.
13.16.1 General installation notes
The D-sub connectors shown in the wiring diagrams have a 4/40 UNC thread.
Max. line length inverter – encoder/resolver:
– 50 m at 70 nF < capacitance per unit length ≤ 120 nF/km
– 100 m at capacitance per unit length ≤ 70 nF/km with DER11B, DEH11B, DE-
H21B, 300 m with DEU21B
Cable cross section: 0.20 – 0.5 mm
If you cut a core of the encoder/resolver cable, insulate the cut-off end of the core.
Use shielded cables with twisted pair conductors and make sure they are groun-
ded on both ends over a large surface area:
– At the encoder in the cable gland or in the encoder plug
– At the inverter in the housing of the D-sub connector
Route the encoder/resolver cables separately from the power cables.
Connecting encoders and resolvers
®
.
2
(AWG 24 – 20)
System Manual – MOVIDRIVE
Installation
13
13
625
®
MDX60B/61B
Table of Contents
loading

This manual is also suitable for:

Movidrive mdx60b

Table of Contents