Startup
14
Startup with DBG60B keypad
14.3.4
Startup procedure
654
System Manual – MOVIDRIVE
INFORMATION
This example refers to a 400 V device.
1. "0" signal at terminal X13:1 (DIØØ "/CONTROL.IN-
HIBIT"), e.g. by disconnecting the electronics terminal
block X13.
2. Press the
key to activate the context menu.
3. Scroll down using the
the menu item "STARTUP".
4. To commence the startup, press the
parameter appears. The flashing cursor under the
parameter number indicates that the keypad is in dis-
play mode.
Use the
key to switch to edit mode. The flashing
cursor disappears.
Use the
or
1" or "PARAMETER SET 2".
OK
Press the
key to confirm your selection.
Press the
key to return to display mode. The
flashing cursor appears again.
Press the
key to choose the next parameter.
5. Select either stand-alone motor or group drive. Press
the
key to choose the next parameter.
6. Select the operating mode you require. Press the
key to choose the next parameter.
7. Select whether an encoder is to be evaluated. Press
the
key to choose the next parameter.
®
MDX60B/61B
key until you have selected
OK
key. The first
key to select "PARAMETER SET
0.00rpm
0.000Amp
CONTROLLER IN-
HIBIT
BASIC VIEW
PARAMETER
MODE
VARIABLE MODE
MANUAL MODE
STARTUP
COPY TO DBG
COPY TO MDX
STARTUP
PREPARE FOR
STARTUP
C00*STARTUP
PARAMETER SET
1
PARAMETER SET
2
C22*MOTORS
SINGLE MOTOR
IDENT. MOTORS
C26*OPER. MODE
1
STANDARD V/F
VFC
C29*encoder
NO
YES
Table of Contents
loading

This manual is also suitable for:

Movidrive mdx60b

Table of Contents