SEW-Eurodrive MOVIDRIVE MDX61B System Manual page 302

Hide thumbs Also See for MOVIDRIVE MDX61B:
Table of Contents
Parameters
8
Explanation of the parameters
P841 Auto reset
P842 Restart time
302
System Manual – MOVIDRIVE
Setting range: Yes/no
DANGER
Risk of crushing if the motor starts up automatically after an auto reset.
Fatal or severe injuries and damage to property.
Do not use the auto-reset function with drives where an automatic restart could
represent a danger to people or devices.
Perform a manual reset.
Yes: Automatically performs a device reset in case of error after an adjustable wait
period. The wait period is adjusted via the parameter P842 Restart time
 (→ 2 302).
A maximum of 5 auto resets are possible during an auto reset phase. If 5 errors
occur that are reset by an auto-reset, no more auto-resets are possible until one of
the following situations occurs:
– a manual reset is performed using the input terminal,
– A
manual
reset
®
MOVITOOLS
MotionStudio engineering software or via the PLC)
– There is a transition to 24 V backup mode, or the device is switched off com-
pletely
Five auto resets are then possible again.
No: No auto reset is performed.
Setting range: 1 – 3 – 30 s
Wait time that should occur between the moment an error occurs and the execution of
an auto reset.
®
MDX60B/61B
is
performed
via
the
serial
interface
(with
the
Table of Contents
loading

This manual is also suitable for:

Movidrive mdx60b

Table of Contents